10
11
3.1 BATTERIES
3.1.1 RECHARGEABLE BATTERY PACK
A Peltor rechargeable battery pack
DC2033
is needed for the main units.
3.1.1.1 CHARGING A BATTERY PACK
A rechargeable NiMH-battery pack
DC2033
has to be charged in a main unit placed in a Peltor charger/holder
DC2064
. It is
sealed according to IP42 for use in dry areas,.
Notice
: See also 3.1.3 TECHNICAL INFORMATION, DC2033 below.
NOTICE!
No other power source than the Peltor DECT-Com II mains adapter
DC2061
(included in the package at delivery)
may be used together with the power supply/holder
DC2064
! It is equipped with exchangeable European, UK and US type
mains connectors, for the input of 100 ─ 240 Volt AC, 50/60 Hz.
3.1.1.2 CHANGE OF INTERNAL BATTERY PACK
àSwitch the unit off by pressing and holding the [
M
] button for approximately 2 seconds.
A voice confirmation “
POWER OFF
” is given and the LED is turned off.
Turn the clip aside (Fig.1) and loosen the screw with a suitable tool (Fig.2). (
Caution
: When loosening the screw, do not use
your fingernail, it can be broken!)
Open the battery lid and replace the battery (Fig.3).
Push the battery pack down firmly to get the connecting plates in contact with the pins.
Hook the battery lid on to the bottom of the unit, close it, press down and tighten the screw again with the tool. (
Caution
:
When tightening the screw, do not use your fingernail, it can be broken!)
Fig.1
Fig.2
Fig.3
Summary of Contents for Peltor DECT-Com II