3M™ MicroTouch™ Controller EX Serial Reference Guide
31
3M Touch Systems, Inc. Proprietary Information – TSD-29087 Rev D
Restore Defaults
Syntax:
<SOH>RD<CR>
Description:
Returns to the factory default operating parameters. The Restore Defaults command
copies the 3M Touch Systems factory default parameters from ROM to the non-volatile
memory (NOVRAM) and then executes a Reset command.
Table 12 lists the factory defaults for the EX serial controller. The Restore Defaults
command is useful in situations where inadvertent commands to the controller have
rendered the sensor inoperative.
Table 12 EX Serial Controller Factory Default Settings
Operating Parameter
Default
Baud Rate
9600
Serial Communication Settings
N, 8, 1
1
Data Format
Format Tablet
Operating Mode
Mode Stream
Return to Factory Calibration
Yes
The Restore Defaults command requires approximately 1.8 seconds. Therefore, the
application program should wait the maximum amount of time and be sure it receives the
command response before issuing another command to the controller.
Note
: After you issue a Restore Defaults command, you must recalibrate your sensor
using a 2-point calibration.
Response:
<SOH>0<CR>
Positive response.
Unit Type Verify
Syntax:
<SOH>UV<CR
1
Some EX1N2 can operate at N, 7, 2.