background image

Performance Data Sheet 

Model: 3MFF100

 

Use Replacement Cartridge 3MFF101

 

The concentration of the indicated substances in water entering the system was reduced to a concentration 

less than or equal to the permissible limit for water leaving the system as specified in NSF/ANSI Standard 42 and Standard 53. 

  

Capacity 6000 Gallons

 

(22,712

 

Liters) 

 Contaminant Reduction Determined by NSF testing. 

 

Contaminant Reduction 

Average Influent 

NSF specified Challenge 

Concentration 

Avg % 

Reduction 

Average Product Water 

Concentration 

Max Permissible Product 

Water Concentration 

NSF Reduction 

Requirements 

NSF Test 

Report 

Chlorine Taste and Odor 

1.9 mg/L 

2.0 mg/L ± 10% 

97.3% 

0.05 mg/L 

N/A 

 50% 

J-00074328 

Nominal Particulate Class I, , 

0.5 to < 1.0 µm 

5,966,667

 

pts/mL

 

At least 10,000 particles/mL 

99.9% 

5517 pts/ml 

N/A 

85% 

J-00037739 

Benzene 

0.014 mg/L 

0.015 mg/L ± 10% 

96.4% 

0.005 mg/L 

0.005 mg/L 

N/A 

J-00074324 

Cyst* 

122,500 cysts/L 

Minimum 50,000 cysts/L 

99.99% 

<1 cyst/L 

N/A 

99.95% 

J-00037737 

Lead pH @6.5 

0.148 mg/L 

0.15 mg/L ± 10% 

>99.3% 

0.001 mg/L 

0.010 mg/L 

N/A 

J-00074321 

Lead pH @8.5 

0.153 mg/L 

0.15 mg/L ± 10% 

>99.3% 

0.001 mg/L 

0.010 mg/L 

N/A 

J-00074322 

P-Dichlorobenzene 

0.235 mg/L 

0.225 mg/L ± 10% 

99.7% 

0.0005 mg/L 

0.075 mg/L 

N/A 

J-00074326 

Toxaphene 

0.015 mg/L 

0.015 mg/L ± 10% 

93.1% 

0.001 mg/L 

0.003 mg/L 

N/A 

J-00074327 

* Based on the use of Cryptosporidium parvum oocysts. 

 

 

Application Guidelines/Water Supply Parameters 

Service Flow 

2.5 gpm  (9.46 lpm) 

Water Supply 

Potable Water 

Water Pressure 

30 -125 psi (207 – 862 kPa) 

Water Temperature 

40º F - 100º F (4.4º C - 38º C) 

 

It is essential that the manufacturer’s recommended installation, maintenance and filter replacement requirements 

be carried out for the product to perform as advertised. See Installation Manual for Warranty information. 

 

Note: 

While the testing was performed under standard laboratory conditions, actual performance may vary. 

 

Replacement Cartridge: 3MFF101 For estimated costs of replacement elements please call 1-800-222-7880 or visit 

our website at 

www.3Mpurification.com

 

 

 

 

 

 

 

 WARNING 

 

To reduce the risk associated with ingestion of contaminants: 

 

Do not use with water that is microbiologically unsafe or of unknown quality without adequate 

disinfection before and after the system. 

Systems certified for cyst reduction may be used on disinfected 

water that may contain filterable cysts

EPA Establishment Number 070595-CT-001

 

 

 

 

Parts and service available from: 

 

3  

 

3M Purification Inc. 

400 Research Parkway 

Meriden, CT 06450, U.S.A. 

Tel   (800) 222-7880 

 

3M is a trademark of 3M Company. 

        (203) 237-5541 

 

© 2010 3M Company. All rights reserved.   

Fax

   (

203) 238-8701 

 

NSF is a trademark of NSF International  

www.3Mpurification.com

   

INSTR2213 0410   

 

CAUTION 

To reduce the risk associated with property damage due to water leakage: 

  •  Read and follow Use Instructions before installation and use of this system. 

  •  Installation and use MUST comply with all state and local plumbing codes. 

  •  Protect filter from freezing, remove replacement filter when temperatures are expected to drop below 40°F 

(4.4°C). 

  •  Do not install systems in areas where ambient temperatures may go above 110°F (43.3°C). 

  •  Do not install on hot water supply lines.  The maximum operating water temperature of this filter system is 

100°F (37.8°C). 

  •  Do not install if water pressure exceeds 125 psi (862 kPa).  If your water pressure exceeds 80 psi (552 

kPa), you must install a pressure limiting valve.  Contact a plumbing professional if you are uncertain 

how to check your water pressure. 

  •  Do not install where water hammer conditions may occur.  If water hammer conditions exist you must 

install a water hammer arrester.  Contact a plumbing professional if you are uncertain how to check for 

this condition. 

  •  Where a backflow prevention device is installed on a water system, a device for controlling pressure 

due to thermal expansion must be installed. 

  •  Do not use a torch or other high temperature sources near filter system, cartridges, plastic fittings or  

plastic plumbing. 

  •  On plastic fittings, never use pipe sealant or pipe dope.  Use PTFO thread tape only, pipe dope properties 

may deteriorate plastic. 

  •  Do not install in direct sunlight or outdoors. 

  •  Do not install near water pipes which will be in path of a drilling tool when selecting the position to mount 

the bracket; 

  •  Mount filter in such a position as to prevent it from being struck by other items used in the area of 

installation (waste baskets, etc.); 

  •  Onsure that the location and fasteners will support the weight of the system when installed and full of 

water. 

  •  Onsure all tubing and fittings are secure and free of leaks. 

  •  Do not install unit if collet is missing. Contact 3M Purification Inc. if collets are missing from any 

fittings. 

 

•  The disposable replacement filter MUST be replaced every 12 months, at the rated capacity or sooner 

if a noticeable reduction in flow rate occurs. 

 

System tested and certified by NSF International against NSF/ANSI Standard  

42 and Standard 53 for the reduction of substances listed below.

 

Summary of Contents for GT 1000

Page 1: ...fter installation leave these instructions with the units for future reference GT 1000 The grounding of electrical equipment such as telephone computers etc to water line a common procedure This grounding may be in the building or may occur away from the building This grounding can cause electrical feedback into a fountain creating an electrolysis which causes a metallic taste or an increase in th...

Page 2: ...sures higher than 105PSI and lower than 20PSI is the responsibility of the installers 6 Water supply 3 8 O D Plastic pex tubing 7 Waste is 1 1 4 IPS Contractors to supply waste trap and service stop valve in accordance with local code 8 Connecting line to be made of unplated copper and should be thoroughly flushed to remove all foreign matter before being connected to unit This unit is manufactured...

Page 3: ... Parts and service available from 3 3M Purification Inc 400 Research Parkway Meriden CT 06450 U S A Tel 800 222 7880 3M is a trademark of 3M Company 203 237 5541 2010 3M Company All rights reserved Fax 203 238 8701 NSF is a trademark of NSF International www 3Mpurification com INSTR2213 0410 CAUTION To reduce the risk associated with property damage due to water leakage Read and follow Use Instructi...

Page 4: ...3 4 MOUNTING HOLES 3 8 THRU X3 6 1 2 6 1 2 ACCESS PANEL 90 QUICK CONNECT 100 0440 TUBING 100 0439 FILTER OPTIONAL 100 0454 REPLACEMENT CARTRIGGE 100 0455 NOZZLE 100 0453 TUBING 100 0439 INLET GRAIN 100 0471 PUSH BUTTON CONCRETE ACCESS PANEL ...

Reviews: