background image

PARTS LIST:

1 GT1000 Bottle Filler, 1 Filter Cartridge (Optional), 1 Plastic drain elbow, 1 Torx driver.

RECOMMENDED TOOLS:

Level, Drill, 3/8” Drive w/ socket set, Slip joint pliers.

REQUIRED PARTS:

3/8” bolts (FOR WOOD,STEEL OR CONCRETE NOT SUPPLIED). A 1-1/4” trap must be used after

waste bend. 3/8” tubing(TO BE USED FOR WATER SUPPLY INLET).

PRODUCT INSTALLATION:

When installing this product, local, state or federal codes should be adhered to.

1. 

These units are to be mounted on a smooth, flat, finished surface with adequate support structure.

2. Install shut-off valve on water supply. (Not Supplied).

3. 

Install unit using 3/8” minimum screws or bolts. (Not Supplied)

4. 

Connect water supply and waste pipe. Water connection and drain must comply with local codes.

5. 

Turn on water supply and check all connections for leaks.

CAUTION

: This unit is rated for inlet water pressure of 20-105 PSI. A pressure reducing regulator should be used

if the inlet water supply exceeds 105 PSI. Any damage caused by reason of connecting this product to supply line

pressures higher than 105PSI and lower than 20PSI is the responsibility of the installers.

6. Water supply 3/8” O.D. Plastic pex tubing.

7. 

Waste is 1-1/4” IPS. Contractors to supply waste trap and service stop valve in accordance with local code.

8. 

Connecting line to be made of unplated copper and should be thoroughly flushed to remove all foreign matter

before being connected to unit. This unit is manufactured in such a manner that it does not in any way cause taste,

odor, color, or sediment problems.

REPLACEMENT FILTER CARTRIDGE

Cartridge: 3MFF101 Cartridge, Manufactured by 3M Purification, Inc.

Call 800-832-7383 to reorder cartridges.

Using Push-In Fitting

To Attach Tubing

Push tubing in as far as it will go. Tubing must be inserted 

past o-ring and hit backstop. Pull tube to ensure it is secure.

To Release Tubing

Push in grey collet to release tubing. With collet

held, pull tubing straight out.

Backstop

Collet

CAUTION

To reduce the risk associated with property damage due to water leakage:

   Ensure all tubing and fittings are secure and free of leaks.

CLEANING:
The cleaning of units should be done with a non acid bathroom cleaner

.

WARRANTY:
All units come with a 2 year manufactures warranty on all steel, 1 year on all internal parts.

Summary of Contents for GT 1000

Page 1: ...fter installation leave these instructions with the units for future reference GT 1000 The grounding of electrical equipment such as telephone computers etc to water line a common procedure This grounding may be in the building or may occur away from the building This grounding can cause electrical feedback into a fountain creating an electrolysis which causes a metallic taste or an increase in th...

Page 2: ...sures higher than 105PSI and lower than 20PSI is the responsibility of the installers 6 Water supply 3 8 O D Plastic pex tubing 7 Waste is 1 1 4 IPS Contractors to supply waste trap and service stop valve in accordance with local code 8 Connecting line to be made of unplated copper and should be thoroughly flushed to remove all foreign matter before being connected to unit This unit is manufactured...

Page 3: ... Parts and service available from 3 3M Purification Inc 400 Research Parkway Meriden CT 06450 U S A Tel 800 222 7880 3M is a trademark of 3M Company 203 237 5541 2010 3M Company All rights reserved Fax 203 238 8701 NSF is a trademark of NSF International www 3Mpurification com INSTR2213 0410 CAUTION To reduce the risk associated with property damage due to water leakage Read and follow Use Instructi...

Page 4: ...3 4 MOUNTING HOLES 3 8 THRU X3 6 1 2 6 1 2 ACCESS PANEL 90 QUICK CONNECT 100 0440 TUBING 100 0439 FILTER OPTIONAL 100 0454 REPLACEMENT CARTRIGGE 100 0455 NOZZLE 100 0453 TUBING 100 0439 INLET GRAIN 100 0471 PUSH BUTTON CONCRETE ACCESS PANEL ...