6.0  MAINTENANCE, SERVICING, STORAGE

6.1 CLEANING:

 Periodically clean the Climb Assist/Fall Arrest System’s metal components with a soft brush, warm water, 

and a mild soap solution. Ensure parts are thoroughly rinsed with clean water. Lubricate the pawl pivot points and the 

counterweight locking cam with a good quality, low temperture silicone grease.

6.2 SERVICE:

 Only 3M or parties authorized in writing by 3M may make repairs to this equipment. If the 

Climb Assist/Fall Arrest System has been subject to fall force or inspection reveals an unsafe or defective conditions, 

remove the system from service and contact 3M regarding replacement or repair.

6.3   REPAIR INFORMATION:

 If repair is needed, remove pin from quick link so shock pack and hook can be removed from 

the system, or remove the quick link. Apply a thread locking compound to the threads of the new quick link and stake the 

pin after assembly. See Table 1 for servicable parts and corresponding repair kits. 

6.4  STORAGE AND TRANSPORT:

 When not in use, store and transport the Climb Assist/Fall Arrest System and associated 

fall protection equipment in a cool, dry, clean environment out of direct sunlight. Avoid areas where chemical vapors may 

exist. Thoroughly inspect components after extended storage.

6.5 DISPOSAL:

 Dispose of the Climb Assist/Fall Arrest if it has been subjected to fall arrest forces or inspection reveals an 

unsafe or defective condition. 

 

;

Remove all attached RFID Tags before disposing of this product. RFID Tags must be disposed of according to the 

restrictions specified in Section 7.

7.0  RFID TAG

7.1 LOCATION:

 3M product covered in these user instructions is equipped with a Radio Frequency Identification (RFID) Tag. 

RFID Tags may be used in coordination with an RFID Tag Scanner for recording product inspection results. See Figure 12 

for where your RFID Tag is located.

7.2 DISPOSAL:

 Prior to disposing of this product, remove the RFID Tag and dispose/recycle in accordance with local 

regulations. For more information, please visit our website: 

http://www.3M.com/FallProtection/RFID

8.0 LABELS

Figure 12 illustrates labels on the Climb Assist/Fall Arrest System. Labels must be replaced if they are not fully legible.

Summary of Contents for DBI SALA OSHA 1926.502(d)(12)

Page 1: ...3M 2019 OSHA 1926 502 d 12 OSHA 1926 502 d 16 iv OSHA 1926 502 d 16 ii OSHA 1910 140 INSTRUCTION MANUAL 5902147 REV J Counterweight Climb Assist Climb Assist Fall Arrest System 1 2 3...

Page 2: ...2 2 1 3 2 4 5 9501600 9503194 9501599 4x 1 2 7 1 16 7 1 16 1 2 3 5 2104153 1200017 1200014 4...

Page 3: ...3 3 4 A B C D E F G A B C 5...

Page 4: ...4 6 A B...

Page 5: ...3 m 85 ft 25 9 m 69 ft 21 m 62 ft 18 9 m 70 ft 21 3 m 99 ft 30 2 m 81 ft 24 7 m 72 ft 21 9 m 80 ft 24 4 m 113 ft 34 4 m 92 ft 28 m 83 ft 25 3 m 90 ft 27 4 m 127 ft 38 7 m 104 ft 31 7 m 93 ft 28 3 m 1...

Page 6: ...6 9 A B C D...

Page 7: ...104 lbs 47 2 kg 93 lbs 42 2 kg 160 lbs 72 6 kg 126 lbs 57 2 kg 111 lbs 50 3 kg 99 lbs 44 9 kg 170 lbs 77 1 kg 134 lbs 60 8 kg 118 lbs 53 6 kg 106 lbs 48 1 kg 180 lbs 81 6 kg 143 lbs 64 9 kg 125 lbs 56...

Page 8: ...8 11...

Page 9: ...DUCTS MARK ED TO ANSI Z359 18 TYPE A MINIMUM BREAKING STRENGTH 5 000 LBS MINIMUM SERVICETEMP 40 F 40 C THIS PRODUCT COMPLIESWITHTHE FOLLOWING STANDARDS ONLY IF MARKED WITHTHE CORRESPONDING LETTER CODE...

Page 10: ...PLIES WITHTHE FOLLOWING STANDARDS ONLY IF MARKED WITH THE CORRESPONDING LETTER CODE UNDER STDS SECTION B OSHA 1910 140 1926 502 D ASTM F887 E ANSIZ359 3 F ANSIZ359 4 H ANSI Z359 15 J COUNTER WEIGHT RE...

Page 11: ...additional connecting devices Ensure that systems assembled from components and subsystems made by different manufacturers are compatible and comply with applicable standards Always consult a Competen...

Page 12: ...l Arrest The structure to which the Climb Assist Fall Arrest is attached must sustain static loads applied in the directions permitted by the Fall Arrest System of at least 3 600 lbs 16 kN with certif...

Page 13: ...quare rung ladders over 9 16 inch diameter up to 1 3 4 inch and round rung ladders over 3 4 inch up to 1 3 8 inch diameter 3511598 4 Counterweight Cable 1 4 inch 7x19 Galvanized 3 ft long Ferrule 1 4...

Page 14: ...Assist Fall Arrest System must be installed so deflection of the anchor line in a fall arrest does not bring the anchor line into contact with a sharp edge or any other article that may damage the anc...

Page 15: ...xamples of inappropriate connections Do not connect snap hooks and carabiners A To a D ring to which another connector is attached B In a manner that would result in a load on the gate NOTE Large thro...

Page 16: ...the climbing surface Attach the harness and Rung Hook Assembly to the wire rope assembly using the provided quick link See Figure 2 3 3 INSTALLING THE SAFETY BLOCK Figure 7 illustrates installation of...

Page 17: ...eight moves freely down the guy wire Do not loosen the tension adjusting nut further than two 2 turns past the point at which the counterweight can move freely down the guy wire If the guy wire angle...

Page 18: ...en not in use store and transport the Climb Assist Fall Arrest System and associated fall protection equipment in a cool dry clean environment out of direct sunlight Avoid areas where chemical vapors...

Page 19: ...e play indicate a need for replacement Clean and reassemble the safety block Lubricate pawl pivot holes with a good quality low temperature silicone grease Inspect the bolts for tightness Ensure the s...

Page 20: ...9 Kitashinagawa Shinagawa ku Tokyo Phone 81 570 011 321 Fax 81 3 6409 5818 psd jp mmm com WEBSITE 3M com FallProtection I S O 9 0 0 1 FM534873 EU DECLARATION OF CONFORMITY 3M com FallProtection DOC U...

Reviews: