background image

1

Summary of Contents for CTM082

Page 1: ...3M ESD Pro User s Guide ESD Event Indicator Model CTM082 ...

Page 2: ...eriodically check that the indicator is functioning properly FCC This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Note This equipment has been tested and found to comply with the lim...

Page 3: ...s solenoids stepper motors and alike In order to separate charge device type events from non related EMI electromagnetic interference events 3M ESD Pro employs a patent pending system that analyzes waveforms of the signals and rejects the ones that are different from a classic shape of an ESD event More specifically CDM charged device model waveform is set as a template In order not to miss ESD ev...

Page 4: ...iagnostics and troubleshooting ESD tool qualification EMI diagnostics and more The 3M ESD Pro detects ESD events by the specific electromagnetic signature these events produce As such the performance of the 3M ESD Pro must be looked at in view of wave propagation Just like with a microphone the farther away from the source of the signal you are the weaker the signal is When searching for the sourc...

Page 5: ... placement on any conductive or even dissipative surface When working with the automated equipment always observe safety precations as recommended by equipment manufacturer and your company s practices ...

Page 6: ...t strength is a factor of many variables the accumulated static voltage the capacitance of the charged objects a larger object holds more charge than a smaller one the physical size of discharging objects the environment the distance from ESD event occurrence Therefore one should exercise good judgement in comparing the strength of ESD events captured under different conditions Threshold Adjustmen...

Page 7: ...raph will show it in red An event below this level will still be shown on the bar graph in green but no count or sound will be produced Setting the Threshold To set a new threshold do not press the switch Rather move its actuator up or down Once the switch begins to move one red LED appears on the bar graph display As the switch moves up and down this red LED moves accordingly and its position ind...

Page 8: ...attery Compartment on the back Controls and Indicators Power Switch Turns power on and off Sound Switch Turns the sound on and off CDM Turns EMI rejection mode on and off Alarm Threshold Adjusts alarm threshold up and down Displays current alarm threshold Resets the Event Counter Event Counter Counts ESD events above the set threshold ESD Event Bar Graph Shows relative ESD event strength CDM Indic...

Page 9: ...are and how many of them occur Thus instruments such as the 3M ESD Pro serve as your ultimate measure of effectiveness of your ESD protection The 3M ESD Pro is capable of rejecting non ESD related EMI electromagnetic interference events This patent pending methodology allows assessment of the ESD environment in places where EMI events resulting from stepper motors solenoids relays and other simila...

Page 10: ...V battery to the battery clips Observe the polarity of the battery Re install the battery door Low Battery Indicator When battery voltage gets low less than 20 capacity remains the low battery indicator on the display appears At this point it is a good idea to install a new battery to assure optimal performance Turning 3M ESD Pro On and Off Move the actuator of the power slide switch to the right ...

Page 11: ...o can produce audible alarm when an event is deleted In order to enable this function move the actuator of sound slide switch to the right The Next Step If you want to further your knowledge of strength of ESD events and have a record of the ESD environment please consider 3M EM Aware ESD Monitors You can find information at www 3M com static Customer and Technical Support For customer and technic...

Page 12: ... or part does contain a substance as detailed in the chart below in excess of the following maximum concentration values in any homogeneous material a 0 1 by weight for lead mercury hexavalent chromium polybrominated biphenyls or polybrominated diphenyl ethers or b 0 01 by weight for cadmium Unless otherwise stated by 3M in writing this information represents 3M s best knowledge and belief based u...

Page 13: ...ithin a reasonable time after written notification of said non conformance and return of said product to 3M 3M shall not under any circumstances be liable for direct incidental special or consequential damages including but not limited to loss of profits revenue or business related to or arising out of this certification including the use misuse or inability to use the product Unless stated otherw...

Page 14: ...源连 接器 Battery snap connector 装置的焊接部 Solder in instrument IC焊接部 Solder in IC 蜂鸣器焊接部 Solder in buzzer 表示该有毒有害物质在该部件所有均质材料中的含量 均在SJ T11363 2006 标准规定的限量要求以下 Indicates that this hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in SJ T11363 2006 表示该有毒有害物质至少在该部件的某一均质材料中 的含量超出SJ T11363 2006 标准规定的限量要求 Indicates that this hazardous substance cont...

Page 15: ...15 ...

Page 16: ...chase order shall have no force or effect unless expressly agreed upon in writing by an authorized officer of 3M Warranty Limited Remedy Limited Liability This product will be free from defects in material and manufacture for a period of one 1 year from the time of purchase 3M MAKES NO OTHER WARRANTIES INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR...

Reviews: