Troubleshooting

Problem

Probable Causes

Solution

Lamp does not illuminate but fan motor
runs.

c. Control Panel door open
d. Lamp changer dial not engaged
e. Mirror Pan obstructed, not fully

deployed

f. Lamp not seated properly
g. Lamp burned out

a. Close control panel door.
b. Fully rotate lamp changer dial.
c. Remove all obstructions from under

mirror pan.

d. Seat lamp squarely in socket.
e. Replace lamp.

Neither lamp nor fan comes on.

a. Projector not plugged in
b. Stage cover not completely closed

c. No power at wall outlet

a. Plug projector into outlet.
b. Close stage cover to engage safety

interlock.

c. Verify outlet has power.

Fan motor does not run but lamp
illuminates.

a. Fan blade/motor is obstructed
b. Fan motor is burned out

a. Call for service.
b. Call for service.

Lamp and fan both work but utility
outlets do not have power
.

a. Outlets overloaded, circuit breaker

tripped

a. Unplug accessories and reset circuit

breaker.  Accessories must not
exceed 5 amps total.

After replacing a burned out lamp, the
new lamp fails.

a. Defective lamp was installed
b. Possible electrical problem

a. Replace lamp again.
b. If new lamp fails immediately, you

may have an electrical problem.  Call
for service.

Short lamp life:  Lamps seem to fail
before expected life span.

a. Defective lamps
b. High line voltage

a. Document actual lamp life, then

contact Lamp Supplier or 3M Service
Information.

Projected image is wider at the top than
bottom (Vertical Keystoning).

a. Screen not aligned at 90

_

 angle to

projected light beam

a. Tilt projection screen toward

projector until image width is equal
at top and bottom.

Projected image higher on one side
(Horizontal Keystoning).

a. Projector not aligned at 90

_

 angle to

screen

a. Rotate projector until image height is

equal on both sides.

Projected image is dim.

a. Dirty stage glass, lenses, mirrors
b. ENX lamp incorrectly installed in

FXL projector

c. EVD Lamps only: condenser lens

bracket not closed

a. Remove surface dirt.
b. Replace incorrect lamp type with

FXL lamp.

c. Close condenser lens bracket.

Projected image does not have uniform
brightness.

a. Lamp alignment

a. Properly seat lamp in socket and/or

fully rotate lamp changer into
position 1 or 2.

Yellow/orange to brown or blue colours
appear in corners of image.

a. Lamp not at best location for

projector to screen distance

a. Rotate colour tuning dial.

Colour, focus or image problem.

a. Optics out of alignment

a. Call for service.

Summary of Contents for 9700

Page 1: ...tprojektor Bedienungsanleitung Retroproyector Manual del operador Lavagna Luminosa Manuale d Uso Overhead Prosjekt r Bruksanvisning Overheadprojector Handleiding Retroprojector Manual do usu rio Overh...

Page 2: ...ador Esperamos que disfrute al usar este producto de alto rendimiento en sus reuni nes cursillos y demostraciones ITALIANO Vi ringraziamo di aver scelto una lavagna luminosa della 3M Questo apparecchi...

Page 3: ...7 cm x 177 cm 213 cm x 213 cm 243 cm x 243 cm 50I x 50I 60I x 60I 70I x 70I 84I x 84I 96I x 96I 9700 EVD F 342 mm 187 cm 74I 217 cm 86I 248 cm 98I 291 cm 114I 327 cm 129I 9700 EVD F 342 mm x 50I x 60I...

Page 4: ...k cord to pull plug from outlet Grasp plug and pull to disconnect 8 Let appliance cool completely before putting away or when replacing lamp 9 To reduce the risk of electric shock do not immerse this...

Page 5: ...ernal machine characteristics for the 9700 Part Identification List 1 Open Projection Head 2 Projection Mirror 3 Mirror Lift Tab 4 Triplet Lens 5 Flip In Magnifier Optional Accessory 6 Head Release Bu...

Page 6: ...Post will lock into place 6 Push head release button and rotate head 90_ until it locks into place 7 Grasp mirror lift tab and raise projection mirror Fold Down Projector 1 Unplug power cord from elec...

Page 7: ...r film transparency on stage glass 4 8 Set High Low lamp setting to desired position See High Low Lamp Setting below 9 Rotate focus knob 5 for clearest image Caution The glass and metal frame on the f...

Page 8: ...w lamp fully and squarely into socket For EVD lamp do not touch bulb glass with fingers Close condenser lens frame and secure with bracket 5 Close stage cover and plug in power cord Color Tuning Rotat...

Page 9: ...lass and Lenses Use 3M Overhead Cleaner 676 to remove surface dirt from the stage glass and projector lens Caution Cleaning the underside of the stage glass or Fresnel lens is not recommended Improper...

Page 10: ...ssible electrical problem a Replace lamp again b If new lamp fails immediately you may have an electrical problem Call for service Short lamp life Lamps seem to fail before expected life span a Defect...

Page 11: ...o de vendas da 3M ou o fornecedor onde adquiriu o seu aparelho COUNTRY COMPANY NAME ADDRESS LOCATION Austria 3M stereich Ges m b H Brunner Fieldstra e 63 A 2380 Perchtoldsdorf Belgium 3M Belgium N V...

Page 12: ...is marked with the letter L or coloured red The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black Replacement fuses of 10 amp should be...

Page 13: ...TA 300 Carro deluxe XX 0034 1164 0 RS 7110 70 0705 6877 2 DY 0210 0010 3 EVD 78 6969 8054 5 HA 5706 Lamp Lampe Lampe Bombilla Lampada Lampe Lamp L mpada EVD 9700 Overhead Cleaner Nettoyant pour r trop...

Page 14: ...Visual Systems Division 6801 River Place Boulevard Austin Texas 78726 9000 Printed in U S A E3M 6 96 78 6970 6359 8 Rev C...

Reviews: