250 µm fi ber

2.6  Close the funnel door and bow start door on the fiber 

holder. Again ensure that the guide funnel is pushed 
completely forward to the end of the fiber holder. 
Pull the fiber back until the fiber tip is flush with 
the end of the funnel. To verify the cleave length is 
still correct, all coatings should align with the hole 
located in the funnel. Close the back clamp. 

Note: for semi-tight buffer fi ber, the 250 µm coating 
may protrude up to 1 mm past the 900 µm buffer. If 
necessary, re-strip, clean and cleave the fi ber to meet 
length requirements.

Fiber coatings

2.7  Place fiber holder in assembly base and slowly slide 

fiber holder forward, toward the connector.

Note: Allow 10 seconds for this movement from the 
time the fi ber begins to enter the boot on the connec-
tor until the fi ber holder bottoms out in the assembly 
base.

10 seconds or a rate of 3 mm/sec

Guide funnel door opened by 
cam on the assembly base

Fiber bow should start when the white line on 
fiber holder aligns with the “BOW START” 
mark on the assembly base

2.8  While slowly sliding the fiber holder toward the 

connector, a bow should start to form in the fiber 
when the white line on the fiber holder aligns with 
the white BOW START line on the assembly base. 
If a bow is not seen, slide the fiber holder back. If 
a bow is not seen, or if a bow is seen before the 
two white lines meet, slide the fiber holder back. 
Re-strip, clean and cleave the fiber, and begin the 
termination process again.

Fiber bow

Release lever

Guide funnel stops when 
ear contacts release lever

No gap between fiber 
holder and actuation 
when fully inserted

2.9  Continue to slowly slide fiber holder towards 

connector until it stops. Verify fiber bow again. 

Note: The fi ber will bow and lift the middle cover 
for rigid fi bers and remain closed for 250 µm and 
especially fl exible 900 µm fi bers. This ensures proper 
fi ber insertion force.

Guide funnel

Place fiber tip here

Hole

Summary of Contents for 8865-C

Page 1: ...3M No Polish ST Connector SM and MM Flat Splice 250 900 µm Instructions 3 November 2012 78 0013 6978 0 B The Network of Networks ...

Page 2: ...lushing for ten minutes Contact a physician Upon skin contact wash with soap and water Product Information Material Safety Data Sheet or call 3M at 1 800 364 3577 or 651 737 6501 24 hours Bare Fiber Handling CAUTION To reduce the risk associated with handling sharp glass fibers Cleaved glass fibers are sharp and can pierce the skin Use tweezers when handling shards and dispose of them properly per...

Page 3: ... protrude more than 1 mm 04 inches beyond where the 900 µm buffer is stripped away One way to help ensure this is to use the clamp on the fiber holder during the stripping process Here s how Place the fiber holder on the fiber facing backwards clamp closet to cut end and 20 cm 8 inches from the end of the fiber Secure the fiber into the SEMI TIGHT BUFFER groove of the clamp Proceed to strip the fi...

Page 4: ...when using loose tube or semi tight buffered fiber 2 5 With the guide funnel fully forward lay the fiber in the central groove along the length of the fiber holder as shown Position it such that the stripped and cleaved portion extends slightly beyond the tip of the guide funnel If the fiber has a noticeable amount of curvature orient it so the curvature is directed downward toward the fiber holde...

Page 5: ...of 3 mm sec Guide funnel door opened by cam on the assembly base Fiber bow should start when the white line on fiber holder aligns with the BOW START mark on the assembly base 2 8 While slowly sliding the fiber holder toward the connector a bow should start to form in the fiber when the white line on the fiber holder aligns with the white BOW START line on the assembly base If a bow is not seen sl...

Page 6: ...nstall it into the receptacle 2 2 reinsert the fiber holder into the assembly base being careful to avoid damaging the fiber and proceed with step 2 12 To remove the connector from the fiber place it into the cap popper cavity on the assembly base oriented as shown Then press down firmly using equal pressure at each end of the connector This action will pop the element activation cap upward thereb...

Page 7: ...h Connector ST Assembly Tool 1 package RoHS Compliant 2002 95 EC means that the product or part Product does not contain any of the substances in excess of the maximum concentration values in EU Directive 2002 95 EC as amended by Commission Decision 2005 618 EC unless the substance is in an application that is exempt under EU RoHS This information represents 3M s knowledge and belief which may be ...

Page 8: ...y Limited Remedy Limited Liability This product will be free from defects in material and manufacture for a period of one 1 year from the time of purchase 3M MAKES NO OTHER WARRANTIES INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE If this product is defective within the warranty period stated above your exclusive remedy shall be at 3M s opt...

Reviews: