3.4 For 2 through 1/0 AWG copper connectors, 2 and 1 AWG aluminum connectors, or connectors with an
O.D. between 0.40–0.55" (10,2–14,0 mm):
Park the cold shrink adapter tube with the
WHITE CORE
on the
insulation.
For 2/0 through 4/0 AWG copper connectors or connectors with an O.D. between 0.50–0.64"
(12,7–16,3 mm):
Park the cold shrink adapter tube with the
RED CORE
on the insulation.
(Figure 10).
Cold shrink adapter tube
Figure 10
3.5 Install connector. See table (on cover) for proper connector dimensions. (For standard 3M
™
Connectors, refer
to table at the end of this instruction for crimping infrmation). Remove any excess oxidation inhibitor from
connector ends if aluminum connector is used
(Figure 11).
Connector
Figure 11
4.0 Install Splice
4.1 Apply a tape marker to semi-con insulation shield on cable which does not contain splice. Measure 8 1/2"
(216 mm) from center of connector
(Figure 12).