background image

2.0  3M

 Indoor Building Entrance  

 

Terminal IPT Location and  

 Mounting 

2.1 

Locate the terminal according to your company’s 

standard operating procedure. Consider the 

following points:

a.  Locate the terminal inside the building/room 

as close as possible to the MGN or ground 

wire source.

b. Locate the terminal inside the building/room 

as close as possible to the cable entrance.

c.  Locate the terminal on a firm mounting 

surface where it will be accessible to all 

technicians at all times.

d. Locate the terminal where it can be reached 

without a ladder.

e.  Avoid locating the terminal where it projects 

out in a hazardous manner.

f.  Avoid locating the terminal where it may 

come in contact with chemicals, liquids or 

vapor as it may cause damage to the plastic 

components.

g. Place covered, solid #6 AWG wire from the 

external ground bar to the approved ground 

source and torque to 40 in.-lbs. (4.52 N•m).

Note: Visually inspect all components. If any component  

is missing or appears damaged, do not install and 

call 3M customer service at 1-800-426-8688 for a 
replacement product.

3M

 Integrated Protection Terminal 4588IPT - 50 pair

3M

 Integrated Protection Terminal 4588IPTN - 50 pair

Note: Failure to properly bond and ground the terminal 

per N.E.C. or local equivalent codes may render the 

protector arrestors useless.

2.2  Remove exterior cabinet door and store in  

safe location.

2.3  Open splicing chamber, remove access panel  

and store in safe location.

2.4  Pull the preterminated block tail, insulated ground 

wire and accessories out of chamber.

2.5  Position terminal at desired location and  

hold in place.

2.6  Using a small screw driver, reach through the 

enclosure above block #1 and mark the upper 

right mounting location on the wall.

Note: use caution when reaching into enclosure with 

screw driver to not damage any of the harness wires.

2.7  Remove terminal from wall and place in a  

safe location.

2.8  Drive one mounting screw into location marked in 

2.6. Tighten such that terminal key hole mounting 

location will fit over the screw head.

2.9  Hang and level terminal onto wall using the screw 

placed in 2.8.  Hold in place.

2.10  While holding terminal level, drive a second 

mounting screw through the terminal mounting 

location into the wall. Can use any other available 

location that is easy to access.

2.11  Drive third mounting screw through final terminal 

mounting location.

3

78-0015-0406-3-C

October 2016

Summary of Contents for 4588IPT Series

Page 1: ...Protection Terminals 4588IPT and 4588IPTN Indoor Building Entrance Terminal with the fire retardant 3M Quick Connect System QCS 2814 Instructions Underwriters Laboratories UL 348X Listed October 2016 78 0015 0406 3 C ...

Page 2: ...PM FR b Splice chamber with strain relief for entrance cable c Insulated 6 ground strap for entrance d External bottom mounted three point ground bar e Binding post log label f 3M Single Pair Test Probe 2827 g Lockable protective cover 1 2 3M Integrated Protection Terminal Dimensions Model Height Width Depth 4588IPT 50 8 5 216 mm 9 229 mm 5 5 140 mm 4588IPT 100 12 305 mm 9 229 mm 5 5 140 mm 4588IP...

Page 3: ...inal 4588IPT 50 pair 3M Integrated Protection Terminal 4588IPTN 50 pair Note Failure to properly bond and ground the terminal per N E C or local equivalent codes may render the protector arrestors useless 2 2 Remove exterior cabinet door and store in safe location 2 3 Open splicing chamber remove access panel and store in safe location 2 4 Pull the preterminated block tail insulated ground wire an...

Page 4: ...e 3M Cable Ties or equivalent 3 11 Route cable to splice chamber making sure gasket lines up and seals to bottom 3 12 Use 3M Cable Ties or equivalent cable ties to secure the entrance cable to the back wall 3 13 Route cable binders to appropriate block tails and splice per your company practice 3 14 Bundle splice conductors and place inside splice chamber 3 15 Replace splice chamber cover 4 0 Inst...

Page 5: ... place close the cap and press to snap the latch firmly into place 5 3 Route the jumper wires to the distribution pair through wire loops on the block ends and through vertical and horizontal wireways Cut jumper wires to appropriate length leaving at least 2 51 mm of slack 5 4 Terminate the jumper wires to the distribution pair by repeating the procedure described in steps 5 1 and 5 2 5 5 Terminat...

Page 6: ... 6113 8035 5 5 2810LT BLGR3601 6000 QCS tagging labels blue green 3601 6000 80 6113 8036 3 5 2810PC P Purple priority cap XS 0038 8516 6 100 2810PC R Red priority cap XS 0038 7407 9 100 2810PC Y Yellow priority cap XS 0038 0280 7 100 2810RC 0 Orange replacement cap XS 0038 7406 1 100 2810RC P Purple replacement cap XS 0038 8599 2 100 2827 Single pair test probe XS 0038 74087 1 SOR OC Cable wire te...

Page 7: ...met to allow the cable conductors to pass through e Remove modules cover bags and push modules through grommet into splice chamber f OR Push grommet up toward blocks and route splice modules through port chamber g Reinstall grommet allowing sufficient block length h Grasp the 1 10 block and align with the top frame tab i Position remaining 4 blocks over respective tabs j Push down with equal press...

Page 8: ... the product which are not contained in 3M s current publications or any contrary statements contained on your purchase order shall have no force or effect unless expressly agreed upon in writing by an authorized officer of 3M Warranty Limited Remedy Limited Liability This product will be free from defects in material and manufacture for a period of one 1 year from the time of purchase 3M MAKES NO...