Fit Check

Perform a positive pressure fit check each time the respirator is 
donned.

Positive pressure Face Fit check

Fitting instructions must be followed each time the respirator is 
worn.

1.  Place the palm of the hand over the exhalation valve cover and 

exhale gently.

2.  If the respirator bulges slightly and no air leakage between 

the face and the respirator is detected, a proper fit has been 
achieved.

3.  If air leakage is detected, re-position the respirator on the 

face and/or readjust the tension of the strap to eliminate the 
leakage.

4.  Repeat the above face fit check
5.  If you cannot achieve a proper fit, do not enter the 

contaminated area. See your supervisor

Important Notice

3M does not accept liability of any kind, be it direct or 
consequential (including, but not limited to, loss of profits, 
business and/or goodwill) arising from reliance upon any 
information herein provided by 3M. The user is responsible for 
determining the suitability of the products for their intended 
use. Nothing in this statement will be deemed to exclude or 
restrict 3M’s liability for death or personal injury arising from its 
negligence.

EU_Master_01

3M is a trademark of 3M company. 

Please recycle. © 3M 2013. 

All rights reserved.

16755

3M Personal Safety Division

EMEA Region

3M Centre,

Cain Road, Bracknell

Berkshire RG12 8HT

United Kingdom

Tel: +44 (0) 1344 858000

www.3M.eu/safety

Summary of Contents for 4000 Series

Page 1: ...cord keeping Easy and secure fitting of neck strap and adjustment of head cradle Optional overspray guard prolongs the life of the particulate filter when paint spraying Maximum product weight of 320 grams Applications The 3M 4000 Series Reusable Half Face Masks come in a variety of different product options 3M 4251 FFA1P2 R D provides protection against organic vapours good warning properties and...

Page 2: ...ation under Article 10 EC Type Examination has been issued for these products by INSPEC International Limited 56 Leslie Hough Way Salford Greater Manchester M6 6AJ UK Notified Body number 0194 Certification under Article 11 EC quality control has been issued by BSI Product Services Notified Body number 0086 Cleaning and Storage If the respirator is to be used for more than one shift it should be c...

Page 3: ...cordance with respirator and filter user instruction leaflet 9 In case of intended use in explosive atmospheres contact 3M technical service 3M definition minimum 19 5 by volume oxygen Fitting Instructions Before assigning any respirator to be worn in a contaminated area we recommend that a qualitative or quantitative fit check be performed before entering the workplace Fitting instructions must b...

Page 4: ...ou cannot achieve a proper fit do not enter the contaminated area See your supervisor Important Notice 3M does not accept liability of any kind be it direct or consequential including but not limited to loss of profits business and or goodwill arising from reliance upon any information herein provided by 3M The user is responsible for determining the suitability of the products for their intended ...

Reviews: