5)  Firmly pull the module away from the head.  (It may be 

necessary to twist the module slightly from side to side.)

6)  Remove the new RO membrane module from its protective 

wrap.  (Double check to see that it is the correct replacement by 
comparing the labels.)  

7)  Remove the sanitary plastic cap atop the module.
8)  Ensure both o-rings are present on the replacement fi lter and are 

seated into grooves; moisten o-rings with water.  DO NOT use any 
petroleum products to lubricate the o-rings.

9)  Connect the new red SFC reject tubing (supplied with replacement 

membrane module) by inserting it into the fitting at the bottom of 
the new RO membrane module as far as it will go, and into the 
faucet adapter.  Line up the module ears, insert the module and 
push it into the head until it is fully seated.  Twist the module 1/4 
turn to the right (clockwise) to lock it into place.

10)  Open the cold water feed valve, and carefully check for leaks.  Carefully 

inspect the fitting at the bottom of the new RO membrane module.

11)  For sanitization of RO system please follow instructions below in 

Section D.

12)  Flush membrane module - refer to Section M, Step 1 and 2 on 

page 8.

D.  SANITIZING THE RO SYSTEM

Follow the sanitizing procedure for the storage tank and the filtration 
assembly outlined below, followed by 24 hour flush with tank empty 
and faucet open.

To help provide you with the highest quality water from your RO 
Drinking Water Filtration System, it is important to routinely sanitize 
both the storage tank and the filtration assembly as noted below.

IMPORTANT NOTE:  These procedures are only intended to be part of 
a routine maintenance program only and are not designed to sanitize 
systems that have become highly contaminated from misuse.

When to Sanitize the Storage Tank
• 

Upon start-up as described in the beginning of this manual.

• 

After any servicing or routine maintenance which involves the RO 

 

membrane module, carbon block post-filter, storage tank or faucet.

When to Sanitize the Filtration System
• 

After any servicing or routine maintenance which involves the 

 

sediment and granulated carbon replacement filters or the RO  

 

 

membrane replacement module.  

How to Sanitize the Storage Tank and Filtration System

Sanitizing the storage tank generally requires:

• 

Common household bleach (5.25% non-scented)

• 

Eye dropper or plastic oral syringe

1)

  Close the cold water feed valve and lift up on the faucet handle to 

 

empty the water in the storage tank.  It should feel light when 

 empty.

2)

  Disconnect the 3/8” yellow tubing (system tank) from the ball 

valve on top of the storage tank.

3)

  Insert into the yellow tubing 1/2 teaspoon (3 ml) of household 

bleach.  (See Fig 8)

4)

  Reconnect the yellow tube to the tank ball valve.

5)

  Close the RO faucet and open the cold water feed valve.

6)

  Wait 4-5 hours.

7)

  Life up the handle of the RO faucet and allow contents of tank to 

drain completely into the sink.

8)

  Sanitizing is now complete.

9)

  If there is any residual chlorine/bleach taste in the next tank full, 

drain tank completely a second time.

E. LONG TERM NON-USE

 

If the RO system is to be left unused for a long period of time 

(greater than 30 days), install new replacement filters.

11

Remove the red SFC tubing from

the fitting before completely

removing the RO membrane module

    

 ON 

    

 OFF 

Fig. 7

WARNING

To reduce the risk associated with ingestion of water contaminated 
with sanitizer:

  • After installation, sanitizers 

must

 be fl ushed from the system 

before fi rst use as directed within the installation instructions.

Summary of Contents for 3MRO401

Page 1: ...ion and Operating Instructions For 3MRO401 Reverse Osmosis Drinking Water Filtration System Installer Please leave manual with homeowner Homeowner Please retain for operation and future maintenance instructions ...

Page 2: ...ated with ingestion of contaminants Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system Systems certified for cyst reduction may be used on disinfected water that may contain filter able cysts EPA Establishment 070595 CT 001 To reduce the risk associated with a hazardous voltage due to an installer drilling through e...

Page 3: ...dition Where a backflow prevention device is installed on a water system a device for controlling pressure due to ther mal expansion must be installed Do not use a torch or other high temperature sources near filter system replacement filters plastic fittings or plastic plumbing On plastic fittings never use pipe sealant or pipe dope Use PTFE thread tape only pipe dope properties may dete riorate ...

Page 4: ... Prepare the system for installation 6 G Install the feed water connection and tubing 7 H Prefill and sanitize the storage tank 7 I Install the drain connection 7 J Install the filtration assembly and storage tank 8 K Make the tube connections 8 L Start up the system 8 M Flush the system and check the operation 8 N Installation troubleshooting 9 II Operation Maintenance Instructions A Important wa...

Page 5: ... be required to seal the connection If drilling is required we strongly recommend you contact a professional installer The faucet should be positioned so that it empties into the sink and the spout swivels freely for convenience Before drilling the hole always check underneath the sink to ensure that nothing will interfere with mounting the faucet such as reinforcing ribs support brackets or the c...

Page 6: ...faucet spout into where the 3 8 tubing was just removed 3 Slide the chrome base plate and rubber washer up the threaded base of faucet 4 Connect the 1 4 green tubing supplied in the installation kit to the smaller barb on the air gap faucet Push it on firmly until it seats 5 Connect the supplied 3 8 black tubing to the larger barb on the air gap faucet Push it on firmly until it seats 6 From above...

Page 7: ...ld water supply making sure the tank valve is still open and allow the tank to fill about 3 minutes 5 Close the cold water supply and the tank valve Disconnect the orange and yellow tube from the union connector setting the tank aside while proceeding with the rest of the installation the sanitizing solution should be kept in the tank for at least 15 minutes Refer to the Using Push In Fittings sec...

Page 8: ... can be set in the front center between the sink basins for ease of access if space permits K MAKE THE TUBING CONNECTIONS With all of the components in place the tubing connections can be made When routing the tubing between the components several guidelines should be observed Tubing runs should generally follow the contour of the cabinet rather than interfere with the cabinet storage area Strive ...

Page 9: ... The drain line has a loop in it Air is locked in the air gap outlet There is excessive RO reject flow Solutions Check to see that the drain line is clear of any obstruction and remove the drain saddle fitting to verify that the hole is drilled through completely Shorten tubing so that it is as vertical as possible Blow air into the air gap outlet using a short length of tubing Disconnect the red ...

Page 10: ...e 5 minutes for the filtration assembly to completely depressurize 2 Remove cover 3 Twist the existing filter 1 4 turn to the left so that the ears on the filter are able to disengage from the head Firmly pull the filter from the head It may be necessary to twist the filter slightly from side to side to help free it 4 Remove the new replacement filter from its protective wrap Double check to see t...

Page 11: ...d are not designed to sanitize systems that have become highly contaminated from misuse When to Sanitize the Storage Tank Upon start up as described in the beginning of this manual After any servicing or routine maintenance which involves the RO membrane module carbon block post filter storage tank or faucet When to Sanitize the Filtration System After any servicing or routine maintenance which in...

Page 12: ...g the warranty period 3M Purification Inc will replace the Product or refund your Product purchase price This warranty does not cover labor The remedy stated in this paragraph is Customer s sole remedy and 3M Purification Inc s exclusive obligation This warranty gives you specific legal rights and you may have other rights which may vary from state to state or country to country For any warranty q...