12.4 Air Line Filter (Figure 12-5)
Periodically check the air line
fi
lter to drain
water and clean as necessary. Do not allow
water to go above the
fi
lter element.
12.5 Circuit Breaker
The case sealer is equipped with a circuit
breaker which trips if the motors are
overloaded. Located inside the electrical
control box on the side of the machine, the
circuit breaker has been preset and requires
no
further
maintenance.
If circuit is overloaded and circuit breaker
trips, unplug machine from electrical power:
1. Determine cause of overload and correct.
2. Plug in machine. Wait two minutes.
3. Press machine “On” (I) button, on the
side guard, to resume case sealing.
12.6 Blade Replacement, Taping Head
See Manual 2, “Maintenance –
Blade (Blade) Replacement”.
Figure 12-5 Air Line Filter
Air Line
Filter
Water Drain
Valve
•
To reduce the risk associated with
mechanical and electrical hazards:
−
Read, understand, and follow all safety
and operating instructions before
operating or servicing the case sealer.
−
Allow only properly trained and quali
fi
ed
personnel to operate and service this
equipment.
•
To reduce the risk associated with sharp
blade hazards:
−
Keep hands and
fi
ngers away from
tape cuto
ff
blades under orange blade
guards. The blades are extremely sharp.
Warning
Warning
12. Maintenance
(continued)
•
To reduce the risk associated with pinches and entanglement hazards:
−
Do not leave the machine running while unattended.
−
Turn the machine o
ff
when not in use.
−
Never attempt to work on any part of the machine, load tape, or remove jammed
boxes from the machine while the machine is running.
Warning