Final Check and Calibration

Pressurize system and check for leaks.  Re-tighten necessary parts to stop any leakage.  Flush
system with compressed air for a minimum of five (5) minutes.  Calibrate the carbon monoxide
monitor as outlined in the CO monitor 

User Instructions

.

Storage

Prior to storage of the unit, check for moisture in the third and fourth stage filters.  If moisture is
present, dry the system and replace the filters.  Dry filters can be left in the unit prior to storage.

RECORD KEEPING

Record all periodic air quality checks; monitor calibration dates, filter cartridge change intervals
and any other service performed on either unit.

TROUBLESHOOTING

Use the table below to help identify possible causes and corrective action for problems you may
experience.

IMPORTANT NOTICE

Warranty

3M warrants its Portable Compressed Air Filter and Regulator Panel for a period of one (1) year
and its Carbon Monoxide Sensor for a period of two (2) years from the original shipping date, to
be free from defects in material and workmanship in normal service and under normal conditions.
This warranty is void if the 3M filter and regulator panel or carbon monoxide sensor has been
damaged by accident, misuse, neglect, improper service, or other causes not arising out of defects
in material or workmanship.  This warranty does not include replaceable items, such as filter
elements, which are considered part of a regular maintenance program.  Any implied warranties
arising out of the sale of 3M’s filter and regulator panel and its carbon monoxide sensor, including
but not limited to the implied warranties of merchantability and fitness for a particular purpose, are
limited in duration to the above one (1) and two (2) year periods respectively.  3M shall not be
liable for loss of use of any of its products or incidental or consequential costs, expenses, or
damages incurred by the purchaser or any other user.

THE FOREGOING WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER
WARRANTIES EXPRESS, IMPLIED, OR STATUTORY, INCLUDING WARRANTY 
OF MERCHANTABILITY.

15

You smell or taste
contaminants or an irritation
occurs.

Airflow too low.

Misuse, improper assembly or
malfunction of equipment.

Filter cartridges may be used up.

Clogged particulate filter.

Pressure too low.

Leave work area immediately
and contact your supervisor.
Do not use until the cause is
identified and corrected.

Replace filter cartridges.

Replace all filter cartridges.

Raise inlet pressure or adjust
regulator.

Problem

Possible Causes

Corrective Action

netzerotools.com

netzerotools.com

Summary of Contents for 256-02-01

Page 1: ... with Carbon Monoxide Monitor User Instructions Keep these User Instructions for reference 3M 256 02 00 Portable Compressed Air Filter Regulator Panel 3M 256 02 01 Portable Compressed Air Filter Regulator Panel netzerotools com netzerotools com netzerotools com ...

Page 2: ...or Panel 256 02 01 with CO Monitor 7 Replacement Parts 8 Accessories 8 Set Up Procedures 8 OPERATING INSTRUCTIONS 10 Carbon Monoxide Monitor 11 3M Portable Compressed Air Filter and Regulator 256 02 01 with Carbon Monoxide Monitor 11 REPLACEMENT PART INSTRUCTIONS 13 Prefilter Combined First and Second Stages 13 Air Scrubber Third and Fourth Stages 14 Final Check and Calibration 15 Storage 15 RECOR...

Page 3: ...at least the requirements of the specification for Grade D breathing air as described in the Compressed Gas Association Commodity Specification G 7 1 1997 in the United States In Canada refer to CSA standard Z180 1 for the quality of compressed breathing air Failure to do so may result in sickness or death There is no assurance that by using the 3M Portable Compressed Air Filter and Regulator Pane...

Page 4: ...versely affect product performance and result in sickness or death Do not use for respiratory protection when atmospheric concentrations of contaminants are unknown or immediately dangerous to life or health unless used in conjunction with a back up escape system or a self contained breathing apparatus supplied air respirator SCBA SAR Leave work areas immediately if Any part of the system becomes ...

Page 5: ...ed and retained 3 The air then enters the second stage of the prefilter C which traps particulate matter larger than 0 3 microns and coalesces liquid aerosols with an efficiency rating of 99 97 The liquid contaminates are trapped in the lower chamber of the prefilter and expelled through the automatic float drain D 4 The third stage E and fourth stage F contain a bed of odor absorbing activated ch...

Page 6: ...h the panel there is resistance to flow called pressure drop The more airflow through the filter and regulator panel the greater the pressure drop The air control devices approved for use with the 3M respirators must be operated within the supply pressure ranges and hose lengths stated in their User Instructions Use Figure 2 along with information on the maximum airflow consumption supply pressure...

Page 7: ...e operated within the supply pressure ranges and hose lengths stated in their User Instructions Failure to do so may adversely affect respirator performance and result in sickness or death You must comply with OSHA standard 29 CFR 1910 134 which states that Airline couplings shall be incompatible with outlets for other gas systems to prevent inadvertent servicing of airline respirators with nonres...

Page 8: ... Aluminum Tube Third Stage 10 Aluminum Tube Fourth Stage 11 Base Bracket 12 Manifold 13 Carbon Monoxide Monitor 14 Manifold Bracket 15 Bracket Bolts 3 each 16 Manifold Bolts 5 each 17 Manifold Washer 5 each 18 Tubing St Elbow 2 each 19 Tubing 20 Air Regulator 21 Outlet Block 22 1 8 Hex Pipe Plug 23 Close Nipple 1 8 24 Air Sample Metering Valve 25 Air Sample Hose Connector 26 Pressure Gauge 0 160 p...

Page 9: ...or panel can be wall mounted right in the case Simply drill holes in the back of case to allow for installation of screws or bolts Use washers on the screws or bolts to prevent the screws from pulling out from the unit The user s supply line to the inlet of the 3M filter and regulator panel should be a minimum of 3 4 I D The air supply entering the filter and regulator panel should meet the follow...

Page 10: ... The frequency of filter change will depend on the quality of the incoming compressed air and how much the panel is used All three 3 filters should be changed at the same time The carbon monoxide alarm will sound to alert the operator that a problem has developed The monitor alarm will sound due to one or more of the following conditions 1 Carbon monoxide levels exceeding a predetermined alarm set...

Page 11: ...g system is oxygen deficient The 3M filter and regulator panel will not increase the oxygen content of the air Use with oxygen deficient air may result in sickness or death The panel should not be used in an Immediately Dangerous to Life or Health atmosphere IDLH unless it is used in conjunction with a back up escape system or a Self Contained Breathing Apparatus Supplied Air Respirator SCBA SAR w...

Page 12: ...urs After warm up period testing check the monitor s calibration Calibrate the carbon monoxide monitor as per the calibration instructions in the CO monitor User Instructions The monitor should be calibrated prior to use and every two weeks thereafter for the first month Calibrate monitor monthly thereafter if used continuously daily or weekly If the monitor is used on a non continuous basis calib...

Page 13: ...ropriate pressure required by the respirator air control device Adjust air sample metering valve s adjustment knob Fig 5 so the black floating ball is within the green boxed area etched on valve body Proper air sample is now being metered to the CO monitor Periodically check to be sure ball is floating freely in this area by turning adjustment knob and noting movement of ball Fig 5 WWARNING To mee...

Page 14: ...r rod of manifold 4 Discard clogged prefilter element 5 Inspect manifold for dirt and contaminants clean as required and inspect O ring 6 located inside manifold for any cuts or cracks Replace O ring if required to prevent air leakage Serious injury could result if the AIR SAMPLE METERING VALVE is not properly adjusted Proper sample airflow to CO monitor is required for monitor to give correct CO ...

Page 15: ... new third stage filter cartridge is pointing DOWN for proper operation 8 Remove sealing label 14 and install new cap gasket on the TOP of the third stage aluminum filter tube assembly 9 Slide the new third stage aluminum filter tube assembly into the air scrubber on the inlet side 10 Remove old fourth stage filter cartridge 15 and cap gasket from the fourth stage aluminum tube 11 Clean the alumin...

Page 16: ...s been damaged by accident misuse neglect improper service or other causes not arising out of defects in material or workmanship This warranty does not include replaceable items such as filter elements which are considered part of a regular maintenance program Any implied warranties arising out of the sale of 3M s filter and regulator panel and its carbon monoxide sensor including but not limited ...

Page 17: ...ty repair service center No charges will be made for repair or replacement Each repaired unit is warranted for sixty 60 days or the remaining portion of the original equipment s warranty whichever is longer THE FOREGOING CONSTITUTES THE SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ANY AND ALL OTHER REMEDIES WHICH MAY BE AVAILABLE This warranty becomes void immediately should any repair of or altera...

Page 18: ...18 3M 2003 Printed in the U S A 38 9017 2842 8 netzerotools com netzerotools com ...

Reviews: