Carbon monoxide monitor will alarm if carbon monoxide concentrations exceed the preset level
(10 ppm USA; 5 ppm Canada). If alarm should sound, remove respirator or activate SCBA and
immediately move to a safe, breathable atmosphere. Have the proper qualified personnel
examine the equipment and make the appropriate corrections before using again.
Failure to do
so may result in sickness or death.
Use of equipment described in these
User Instructions
must be in accordance with applicable
health and safety standards, respirator selection tables contained in such publications as
ANSI Z88.2-1992, CSA Standard Z94.4, or pursuant to the recommendations of an industrial
hygienist. The employer must have a written respirator program in place which is in
accordance with the OSHA respiratory protection standard found in 29 CFR 1910.134 prior to
using any respirator. In Canada, follow CSA Standard Z94.4 or the requirements of the
authority having jurisdiction in your region.
Each person using this equipment must read and understand the information in these
User
Instructions.
Use of this equipment by untrained or unqualified persons, or use that is not in
accordance with these
User Instructions,
may adversely affect product performance and
result
in sickness or death.
Do not use for respiratory protection when atmospheric concentrations of contaminants are
unknown or immediately dangerous to life or health, unless used in conjunction with a back-up
escape system or a self-contained breathing apparatus/supplied air respirator (SCBA/SAR).
Leave work areas immediately if:
– Any part of the system becomes damaged.
– Air flow into the respirator is reduced or stops.
– Breathing becomes difficult.
– Dizziness or other distress occurs; or
– You taste or smell contaminants or an irritation occurs.
Never alter or modify this assembly.
Not for use in any way other than in accordance with the use and maintenance instructions in
this manual.
Do not use if any parts are missing or damaged.
Air supply piping, fittings, and compressors must have the capacity to deliver sufficient air
volume to operate each air regulating valve at the recommended pressure.
Serious injury could result if the AIR SAMPLE METERING VALVE is not properly adjusted.
Proper sample airflow to CO monitor is required for monitor to give correct CO level readout.
Failure to do so may result in sickness or death.
Always turn off air supply and bleed air pressure before disassembling the 3M filter and
regulator panel or
serious injury could result.
W
WARNING
3
CAUTION
This panel will not remove carbon monoxide.