Material T0/T1 feed malfunction detected
–
the extrusion quality indicator value has exceeded the threshold value
1.
If this error occurs, unload and load again the material using the
Change model material / Change support material
option
in the printer menu
and then resume printing using the
Resume
option.
2.
If the
Change material
procedure is not completed successfully,
you should follow the description in chapter III, point 4.3.
If the problem persists and points 1 and 2 do not help, check that:
•
the printer referencing takes place at a proper height (chapter III, point 3.1),
•
material has been loaded correctly and there are no factors that can hinder its movement,
•
the material is not damp (otherwise, characteristic air bubbles occur on the filament during extrusion),
•
the bowden tube is not mechanically damaged.
If this error occurs repeatedly,
replace the hotend with a new one
and contact the technical assistance department.
Encoder T0/T1 Communication Fail
–
error in communication with the T0/T1 extrusion quality sensor
If this error occurs, contact the technical assistance department.
Encoder T0/T1 Read Fail
–
error in reading the T0/T1 extrusion quality sensor position
If this error occurs repeatedly, contact the technical assistance department.
Encoder T0/T1 Magnitude Fail / Encoder T0/T1 Magnetic field Fail
–
problem with the position of the extrusion quality
sensor's magnetic element
If this error occurs, contact the technical assistance department.
LCD Fail
–
communication error of the controller of the printer's LCD control panel
If this error occurs, contact the technical assistance department.
UI Engine Fail
–
displaying error of the controller of the printer's LCD control panel
If this error occurs, contact the technical assistance department.
Temperature sensor fail - error in readout of heatbed temperature
If this error occurs, contact the technical assistance department.