21
4.7.
SETTINGS
In the settings menu you can apply your
own settings, reset to defaults and enable
or disable the hopper sensor check. After
choosing ‘Apply’, the machine will save
these settings until you edit and apply new
settings or until choosing a new material.
Scroll down in this screen for all options.
The ‘Cancel’ button restores the settings to
the state before entering the menu and the
main menu will be shown.
Please note, we have included default settings
for the first use.
The list below is summary of the settings functionality:
Setting name
Information
Heater [n]
The heater setpoints of the active material
profile are the default settings of the
heaters. In the settings menu the user can
edit the temperature temporary without
editing the selected material profile.
Extruder speed
Screw rotation speed in RPM
Filament fan speed
Filament cooling fans, speed in
percentage.
Filament diameter
Filament extrusion diameter in
millimetres.
Empty spool diameter, full spool
diameter, spool width and
positioner right
Spooling related settings, see spooling -
running chapter.
Spooling speed (toggle)
Automatic for calculated winding and
Manual for fixed positioner and winder
speed. Automatic is recommended as
settings.
Hopper empty check
Hopper sensor enabled when ‘on’, sensor
disabled when ‘off’ is applied.