92
3D SYSTEMS, INC
.
PN:80-D27 Rev.B
Chiller filter replacement
The chiller filter must be cleaned every 6 months.
Parts required :
•
1 x New filter element - part number 1003283E00
•
5L container
•
Demineralized water
Caution: wear PPE (disposable rubber gloves, anti-static coverall, FFP3 respiratory protection, anti-static
safety shoes) .
1 . Switch off the printer (see section "Shutting printer down" on page 66) .
2 . Lock out and tag out the printer: position the main switch from the supply cabinet to position ”O”, then put a lock with a
tag out label on the switch . This will disconnect and isolate the printer from energy during the maintenance .
3 . Open the access door of the supply cabinet .
4 . Close the input and output valves (A and B) .
5 .
Unscrew the transparent filter cover and remove it by pulling downwards in order to reveal the inserted filter element.
6 .
Replace the old filter element with the new one.
7 .
Screw the transparent filter cover.
8 .
Check that the filter is correctly fitted.
9 . Open the input and output valves (A and B) .
10 . Re-start the printer (see section "Powering up the printer" on page 37) .
11 . Check the cover, its mounts and the hoses for leaks .
Caution: do not operate the chiller without the chiller filter.
A
B