81
3D SYSTEMS, INC
.
PN:80-D27 Rev.B
Front and Back casings cleaning
Part required :
•
Vacuum cleaner equipped with wet separator and be explosion proof .
•
Natural fiber brush
•
Damp cotton cloth
Caution: Personal Protective Equipment (PPE) must be used to protect the user against health or
safety risks during working tasks . Wear disposable rubber gloves, anti-static coverall, anti-static safety
shoes and safety glass . Wear disposable dust mask rated FFP3 or N99 level protection at minimum ; we
recommand the use of powered air purifying respirator .
The steps from 1 to 13 are performed to clean the front casings .
1 . Move the feeding piston and the sintering piston to the position 200mm .
2 . Switch off the printer (see section "Shutting printer down" on page 66) .
3 .
Switch the locking key to position “0”, remove the key and keep it with you. This will prevent any power up of the printer
during the maintenance .
4 . Remove the protective guard (1) and open the bottom access doors (2) .
5 . Remove the 3 cover panels .
WARNING: FIRE AND EXPLOSION HAZARDS .
COMBUSTIBLE DUST INSIDE . METAL POWDERS ARE FLAMMABLE AND POTENTIALLY EXPLOSIVE,
ESPECIALLY WHEN DISPERSED IN A CLOUD AND EXPOSED TO AN IGNITION SOURCE SUCH AS HEAT OR
STATIC ELECTRICITY SPARK . OPERATORS AND SERVICE PERSONAL SHOULD AVOID DISTURBING POWDER
MANIPULATE CAREFULLY TO AVOID AS MUCH AS POSSIBLE SUSPENDING OF FINE PARTICLES) .
1
2
Panels to be removed