EN - English - I
nstruc
tions manual
6
MNVCEXHCJP_1504_EN
• Make sure that the installation complies with local
regulations and specifications.
• This device must be installed out of the reach of
the user or of anyone who might happen to touch
it by chance.
• Before doing any technical work on the device,
disconnect the power supply.
• Do not use power supply cables that seem worn
or old.
• Only qualified technical personnel should be
allowed to open the device, and they should
work in a non-explosive atmosphere. Tampering
with the device will invalidate the guarantee. The
manufacturer declines all responsibility for any
damage caused by non-qualified personnel and by
an improper use of the appliances mentioned in
this manual.
• Do not allow children or untrained people to use
the device.
• The device can only be considered to be switched
off when the power supply has been disconnected
and the connection cables to other devices have
been removed.
• Before powering the device install an overload
protection device in the electrical equipment for
the building.
• The user must install neither any apparatus inside
the device if it generates dangerous radiation.
Don’t put any devices which are non-certified into
the housing.
• For technical services, consult only and exclusively
authorized technicians.
• Keep this handbook carefully; it must be available
for consultation on the installation site.
• Never, under any circumstances, make any
changes or connections that are not shown in this
handbook: improper use of the device can cause
serious hazards, risking the safety of personnel and
of the system.
• Use only original spare parts.
• Before proceeding with installation check the
supplied material to make sure it corresponds
to the order specification by examining the
identification labels (
4.2 Product markings,
page 7
).
• Make sure not to cause any impact against the
device when user opens product box. And also
make sure that it is intact and that there are no
signs that it has been dropped or scratched.
4 Identification
4.1 Product description and type
designation
The TS-EXHS series explosion-proof housing has
been designed for use with cameras operating in
industrial environments in which there may be an
explosive atmosphere due to gas, vapors, mists, or air
or powder mixtures.
TS-EXHS housings comprise solid, cast Anticorodal
aluminum alloy from the AlSi7Mg EN AB-42000
group, the exact chemical composition of which is
defined in the UNI EN 1706 standard.
All parts are powder-painted and oven-cured
or treated with special coatings giving excellent
resistant to UV light, to salt spray and to atmospheric
pollutants. Take extra care neither to scratch nor peel
the outer surface off.
The camera body comprises a cylindrical tube, with
a flange that houses a strong, transparent glass;
opposite to the glass there is another flange that, as
well as closing the cylinder, also supports the plate to
which the camera is to be attached.
The housing has two holes for 3/4” NPT cable glands.
These cable glands guarantee an IP66 protection
level.
Cable glands and blanking plug are optional, which
should be certified.
Summary of Contents for TS-EXHS
Page 2: ......
Page 3: ...EN English Instructions manual Ref Manual S13 F1201 C002 TS EXHS Explosion proof camera ...
Page 4: ......
Page 6: ...EN English Instructions manual 4 MNVCEXHCJP_1504_EN ...
Page 15: ...JA 日本語 取扱説明書 Ref Manual S13 F1201 C002 TS EXHS 耐圧防爆カメラ ...
Page 16: ......
Page 18: ...JA 日本語 取扱説明書 4 MNVCEXHCJP_1504_JA ...
Page 27: ......