To do…
Use the command…
Remarks
Optional
The default timeout time of a user
interface is 10 minutes.
With the timeout time being 10
minutes, the connection to a user
interface is terminated if no
operation is performed in the user
interface within 10 minutes.
Set the timeout time for the
user interface
idle-timeout minutes
[
seconds
]
You can use the
idle-timeout
0
command to disable the timeout
function.
Note that if you configure to authenticate the users in the scheme mode, the command level available to
users logging in to a switch depends on the command level specified in the
service-type terminal
[
level level
] command.
Configuration Example
1) Network
requirements
Assume the switch is configured to allow users to log in through Telnet, and the user level is set to the
administrator level (level 3). Perform the following configurations for users logging in through the
console port (AUX user interface).
z
Configure the local user name as
guest
.
z
Set the authentication password of the local user to
123456
(in plain text).
z
Set the service type of the local user to Terminal and the command level to 2.
z
Configure to authenticate the users in the scheme mode.
z
The baud rate of the console port is 19,200 bps.
z
The screen can contain up to 30 lines.
z
The history command buffer can store up to 20 commands.
z
The timeout time of the AUX user interface is 6 minutes.
2) Network
diagram
Figure 2-7
Network diagram for AUX user interface configuration (with the authentication mode bein
scheme)
g
3) Configuration
procedure
# Enter system view.
2-14