232
A
PPENDIX
B: M
ANAGEMENT
S
OFTWARE
U
PGRADE
U
TILITY
c
Copy the management software file to the
upgrade
directory on the
hard drive.
d
Change your directory to the
upgrade
directory on the hard drive.
5
At the MS-DOS prompt, enter the upgrade command:
update <file>
<file>
is the name of the management software file. Note that the
software files have the format
s2sxx_yy.bin
, where
xx_yy
is the
version number.
CAUTION:
You must use the
s2sxx_yy.bin
format, otherwise the
upgrade fails.
You can also use the following parameter with the upgrade command to
specify the serial (COM) port to use for the PC (COM 1) or (COM 2). The
default for this is COM 1:
-c 1
or
-c 2
An example of the upgrade command with this parameter is:
update -c 1 s2sxx_yy.bin
6
Power-down the Switch.
7
At your PC, press [Return].
8
Power-up the Switch immediately (within 5 seconds).
The utility transfers the management software to the Switch.
When the management software has been transferred, your PC displays
the following message:
Update completed successfully.
Update another unit? (y/n)
9
If you want to upgrade the management software of another Switch,
enter
y
(for yes), otherwise, enter
n
(for no).
Summary of Contents for SuperStack II
Page 12: ......
Page 18: ......
Page 42: ......
Page 154: ...154 CHAPTER 4 WORKING WITH THE COMMAND LINE INTERFACE ...
Page 156: ......
Page 162: ...162 CHAPTER 5 PORT TRUNKS ...
Page 169: ...VLANs and Your Switch 169 Figure 32 Forwarding unknown 802 1Q tags ...
Page 173: ...VLAN Configuration for Beginners 173 Figure 34 Simple example Untagged connections using hubs ...
Page 180: ...180 CHAPTER 6 VIRTUAL LANS VLANS ...
Page 188: ...188 CHAPTER 7 FASTIP ...
Page 200: ...200 CHAPTER 9 SPANNING TREE PROTOCOL Figure 49 STP configurations ...
Page 210: ...210 CHAPTER 10 RMON ...
Page 211: ...IV PROBLEM SOLVING Chapter 11 Problem Solving ...
Page 212: ......
Page 224: ...224 CHAPTER 11 PROBLEM SOLVING ...
Page 226: ......