Unit Overview — Front
1-7
100BASE-TX Ports
The Switch 3000 TX has eight Fast Ethernet
100BASE-TX RJ45 ports configured as MDIX
(cross-over), which provide connection to other Fast
Ethernet devices such as the SuperStack II Switch
1000. The maximum segment length is 100m
(328ft) over category 5 UTP or STP cable.
As these ports are configured as MDIX (cross-over),
you need to use a cross-over cable to connect to
devices whose ports are MDIX-only. Most of the
100BASE-TX ports in 3Com devices are MDIX-only.
LEDs
describes the LED behavior on the Switch
3000 TX. For more details about corrective action in
the event of a problem, refer to
Table 1-1
LED behavior
LED
Color
Indicates
Port Status LEDs (ports 1 – 8)
Packet
Yellow
Frames are being transmitted/received
on the port.
Status
Green
Link is present; port is enabled.
Green flashing
Link is present; port is disabled.
Off
Link is not present.
Plug-in Module Status LEDs (port 9)
Packet
Yellow
Frames are being transmitted/received
on the Plug-in Module port.
Status
Green
Link is present; port is enabled.
Green flashing
Link is present; port is disabled.
Green flashing
(long on, short off)
Refer to the “
SuperStack II Switch ATM
OC-3c Module User Guide”.
Yellow
Plug-in Module has failed its Power On
Self Test (if the MGMT LED is flashing
yellow), or the agent software of the
Plug-in Module is not installed correctly.
Yellow flashing
Plug-in Module is not recognized.
Off
Link is not present or the Plug-in Mod-
ule is not installed in the Switch.
Unit Status LEDs
Power
Green
Switch is powered-up.
MGMT Green
Switch is operating normally.
Green flashing
Switch or Plug-in Module is either
downloading software or initializing
(which includes a Power On Self Test).
Yellow
Switch has failed its Power On Self Test.
Yellow flashing
Plug-in Module has failed its Power On
Self Test.
Summary of Contents for SuperStack II 3000 TX
Page 13: ...Network Configuration Examples 1 5 Figure 1 2 Increasing port density with the Switch 3000 TX ...
Page 14: ...1 6 CHAPTER 1 GETTING STARTED Unit Overview Front Figure 1 3 Switch 3000 TX front view ...
Page 16: ...1 8 CHAPTER 1 GETTING STARTED Unit Overview Rear Figure 1 4 Switch 3000 TX rear view ...
Page 20: ...1 12 CHAPTER 1 GETTING STARTED ...
Page 23: ...Configuration Rules with Full Duplex 2 3 Figure 2 1 Fast Ethernet configuration rules ...
Page 96: ...5 28 CHAPTER 5 ADVANCED MANAGEMENT ...
Page 122: ...C 6 APPENDIX C TROUBLE SHOOTING ...
Page 123: ...D PIN OUTS Null Modem Cable 9 pin to RS 232 25 pin PC AT Serial Cable 9 pin to 9 pin ...
Page 124: ...D 2 APPENDIX D PIN OUTS Modem Cable 9 pin to RS 232 25 pin RJ45 Pin Assignments ...
Page 136: ...6 GLOSSARY ...