Upgrades
5-7
Removing the Cover
Follow these steps to remove the server cover:
1
Shut down the server, as described in “Shutting Down”.
WARNING:
Before removing the cover, be sure the unit is turned off and the
power cord is either disengaged from the unit’s receptacle or unplugged
from the wall socket.
2
If the server is mounted in a rack, remove it from the rack. Remove the
rack-mounting brackets from the sides of the server.
3
Use a #1 Phillips screwdriver to remove the black screws on the sides of the
cover.
4
Grasp both sides of the cover and carefully lift it off.
Replacing or Adding
a 16-Port
Asynchronous
Module
The following procedure describes replacing or adding a 16-port
asynchronous module to a CS/3000 series server that has already been
turned on and has been running communications server software. For
instructions on installing a 16-port asynchronous module in a server that
has never been turned on, refer to “Installing 16-Port Asynchronous
Modules”.
This procedure requires you to handle a 16-port asynchronous module.
Whenever you handle one of these modules, adhere to the following ESD
guidelines:
■
Keep the new module in its antistatic bag until you are ready to install it.
■
Do not touch pins, leads, or solder connections on the board.
■
Handle the board by the edges only.
■
Observe proper grounding techniques, including using a foot strap and
grounded mat or wearing a grounded static discharge wrist strap.
You need a #1 and a #2 Phillips screwdriver and a small slotted screwdriver.
To replace or add a 16-port asynchronous module, follow this procedure:
1
Make sure server power is off and the power cord is unplugged.
2
Remove the cover, as described in “Removing the Cover”.
CS3000BookFile Page 7 Tuesday, October 15, 1996 5:12 PM