4-4
C
HAPTER
4: C
ONFIGURATION
6
When you are finished changing firmware configuration parameters, press
the Escape key to return to the Firmware Configuration Utility menu.
7
Press the Escape key again to exit to the monitor prompt.
8
Press the reset switch or power off the server to exit monitor mode.
* Default.
Table 4-1
Firmware Configuration Parameters
Parameter
Values
1. J1 baud rate
1. 110
2. 300
3. 1200
4. 2400
5. 9600
*
6. 19200
7. 38400
2. J2 baud rate
1. 110
2. 300
3. 1200
4. 2400
5. 9600
*
6. 19200
7. 38400
3. Continuous self-test
d - Disable
*
e - Enable
4. Auto-reboot
m - Boot monitor
r - Reboot only
*
u - Upload then reboot
5. Initial boot source
a - Auto
*
f - Floppy
m - Monitor
n - Network
6. Number of reboots
r - Reset
7. Network boot string
_cs30
*
8. Boot retries
O - Try One Time
F - Try Forever
*
9. Boot protocol
B - BTP Boot
S - SLP Boot
*
T - TFTP Boot
A. Change IP/TFTP parameters See “Change IP/TFTP Parameters”.
B. Memory test bypass
D - Disable
*
E - Enable
CS3000BookFile Page 4 Tuesday, October 15, 1996 5:12 PM