Troubleshooting Using the Status LEDs
5-3
Troubleshooting
Using the Status
LEDs
In certain situations, the status LEDs may not light. This section
describes the following:
■
Troubleshooting Using the Module Status LED
■
Troubleshooting Using the Port Status LEDs
Troubleshooting
Using the Module
Status LED
outlines possible causes and some solutions for
troubleshooting the Module Status LED.
Table 5-1
Troubleshooting Using the Module Status LED
LED
State
Possible Cause
Corrective Action
OFF
Hub power is off
Check the controller module power
LEDs.
The module or slot is faulty
Try a different module.
Remove and re-insert the module.
The hub does not have
enough available power for
a new module installation
Use the SHOW POWER BUDGET
management command to ascertain
available power in the hub (see the
Distributed Management Module
Commands Guide
for more
information).