3Com Baseline 2016 User Manual Download Page 2

Numbered elements in this diagram refer to numbered sections in 
the text. A 24-port unit is shown. 

Front Panel

1

24 RJ-45 10/100 Ports

WARNING

: RJ-45 ports.

 These are shielded RJ-45 data 

sockets. They cannot be used as standard traditional 
telephone sockets, or to connect the unit to a traditional 
PBX or public telephone network. Only connect RJ-45 
data connectors, network telephony systems, or network 
telephones to these sockets. Either shielded or unshielded 
data cables with shielded or unshielded jacks can be 
connected to these data sockets.

AVERTISSEMENT: Les ports RJ-45.

 Ceux-ci sont 

protégés par des prises de données. Ils ne peuvent pas 
être utilisés comme prises de téléphone conventionnelles 
standard, ni pour la connection de l’unité à un réseau 
téléphonique central privé ou public. Raccorder seulement  
connecteurs de données RJ-45, systèmes de réseaux de 
téléphonie ou téléphones de réseaux à ces prises. Il est 
possible de raccorder des câbles protégés ou non 
protégés avec des jacks protégés ou non protégés à ces 
prises de don.

WARNUNG: RJ-45-Porte

. Diese Steckdose sind 

geschützte Datensteckdosen. Sie dürfen weder wie 
normale traditionelle Telefonsteckdosen noch für die 
Verbindung der Einheit mit einem traditionellem privatem 
oder öffentlichem Telefonnetzwerk gebraucht werden.  
Nur RJ-45-Datenanscluße, Telefonnetzsysteme or 
Netztelefone an diese Steckdosen anschließen. Entweder 
geschützte oder ungeschützte Buchsen dürfen an diese 
Datensteckdosen angeschlossen werden.

ADVERTENCIA: puertos RJ-45

. Son conectores de datos 

RJ-45 blindados. No pueden utilizarse como tomas de 
teléfono tradicionales estándar ni para conectar la unidad 
a una central de conmutación PBX tradicional ni a una 
red telefónica pública. Conecte sólo conectores de datos 
RJ-45, sistemas de telefonía de red local o teléfonos de 
red local a estas tomas. Es posible conectar cables de 
datos blindados o sin blindar con clavijas blindadas o sin 
blindar a estos conectores de datos.

10BASE-T/100BASE-TX Ports

The Switch has 16 (3C16470B) or 24 (3C16471B) 10/100 Mbps 
auto-negotiating ports. To connect a device to the Switch, use 
Category 5 unshielded or shielded (screened) 100 Ohm TP cable 
(or Category 3 cable for a 10 Mbps connection). The maximum 
length of cable for each connection is 100m (328ft). Connect one 

end of the cable to an RJ-45 port on the Switch, and the other 
end to the appropriate RJ-45 port on the connecting device.

Each port on the Switch is auto-negotiating: its speed and duplex 
mode (half duplex or full duplex) are automatically determined by 
the capabilities of the connected device. 

Each port supports automatic MDI/MDI-X detection and can be 
connected to either a 10BASE-T or a 100BASE-TX device.

I

f you connect two Switch units together, the link 

between them operates at 100 Mbps full duplex. You 
must use Category 5 cable when connecting the units.

CAUTION: 

The Switch supports full duplex auto-negotia-

tion. If the connected device does not support auto-nego-
tiation, the Switch will operate in half duplex mode (even 
if the device is operating in full duplex mode). In such a 
configuration, you may notice some degradation of net-
work performance. 3Com recommends that you use 
devices that are capable of auto-negotiation (and that 
you ensure that auto-negotiation is enabled, if it is a con-
figurable option).

2

Activity/Link/Speed Status LEDs

The first (top) and third row of LEDs, which are colored yellow or 
green, show the activity and speed status of the related ports:

3

Duplex Status LEDs

The second and fourth (bottom) row of Status LEDs, which are 
colored yellow, show the duplex status of the related ports:

H

OW

 

TO

 U

SE

 

THE

 2016/2024 S

WITCH

1

2

3

4

6

5

16

1

13

4

17

5

8

20

9

12

21

24

Ba

s

eline 

S

wit

c

h 2024

Status

Meaning

On

The link has been established.

Flashing

Packets are being received or transmitted on the port.

Off

If the link has not been established, either nothing is 
connected to the port, or there is a problem:

Check that the attached device is powered on.

Check that the cable is the correct type and is not faulty.

If these checks do not identify the cause of the problem, it 
may be that the unit or the device connected to the port is 
faulty. Contact your supplier for further advice.

Green

The link is operating at 100 Mbps.

Yellow

The link is operating at 10 Mbps.

Status

Meaning

On Yellow

The port is operating in full-duplex mode.

Off

The port is operating in half-duplex mode.

!

2

Summary of Contents for Baseline 2016

Page 1: ...witch is suited for office use where it can be free standing or rack mounted in a wiring closet or equipment room The Switch comes with One power cord for use with the Switch Four self adhesive rubber pads One mounting kit The Switch is powered from the AC mains supply The Switch provides high performance switched connections to 10 Mbps and 100 Mbps hubs servers and workstations that require a ded...

Page 2: ...e Switch use Category 5 unshielded or shielded screened 100 Ohm TP cable or Category 3 cable for a 10 Mbps connection The maximum length of cable for each connection is 100m 328ft Connect one end of the cable to an RJ 45 port on the Switch and the other end to the appropriate RJ 45 port on the connecting device Each port on the Switch is auto negotiating its speed and duplex mode half duplex or fu...

Page 3: ...e Rack Mounting The Switch can be mounted in a 19 inch equipment rack using the Mounting Kit Refer to Mounting Kit Instructions on page 5 Power Up Use the following sequence to power up the Switch 1 Check the network connections and cables 2 Connect the power supply cable to the appropriate power socket on the rear panel of the unit refer to 6 Power Supply 3 Connect the plug to the power supply ou...

Page 4: ...don électrique Il doit être agréé dans le pays d utilisation Bitte unbedingt vor dem Einbauen des Switches die folgenden Sicherheitsanweisungen durchlesen WARNUNG Die Installation und der Ausbau des Geräts darf nur durch Fachpersonal erfolgen Wenn der Switch 2016 2024 mit anderen 3Com Hubs oder Switch gestackt werden soll müssen grössere Geräte unter den schmaleren Hubs eingebaut werden Das Gerät ...

Page 5: ...guidelines given in Positioning the Switch on page 3 Rack Mounting the Units The Switch is 1U high and will fit a standard 19 inch rack CAUTION Disconnect all cables from the unit before continuing Remove the self adhesive pads from the underside of unit if already fitted 1 Place the unit the right way up on a hard flat surface with the front facing towards you 2 Locate a mounting bracket over the...

Page 6: ...du Canada VCCI Statement 3Com offers product registration case management and repair services through eSupport 3com com You must have a user name and password to access these services which are described in this appendix Register Your Product to Gain Service Benefits To take advantage of warranty and other service benefits you must first register your product at http eSupport 3com com 3Com eSuppor...

Page 7: ...ber RMA by FAX using this number 61 2 9937 5048 or send an email at this email address ap_rma_request 3com com Europe Middle East and Africa Telephone Technical Support and Repair From anywhere in these regions not listed below call 44 1442 435529 From the following countries call the appropriate number Austria Belgium Denmark Finland France Germany Hungary Ireland Israel Italy 0800 297 468 0800 7...

Page 8: ...py please contact 3Com and a copy will be provided to you Unless otherwise indicated 3Com registered trademarks are registered in the United States and may or may not be registered in other countries 3Com and the 3Com logo are registered trademarks of 3Com Corporation Other brand and product names may be registered trademarks or trademarks of their respective holders General Environmental Statemen...

Reviews: