2. XENPAK Optical Module  

2.1  Appearance and front panel  

 

Figure 4  

Appearance of a XENPAK optical  module 

 

Figure 5  

Front panel of a XENPAK optical  module  

2.2  Installation  

Step 1: Put on an ESD-preventive wrist strap and verify it is properly 
grounded. Then remove the XENPAK optical module from the package. 

 
Step 2: Loosen the two mounting screws on the small cover plate in the 
middle on the filler panel with a screwdriver and remove the small cover 
plate. 

 

Note: When installing a XENPAK optical module, you do not need to 

remove the entire filler panel. Just remove the small cover 
plate in the middle on the filler panel. 

 

Step 3: Hold the fastening screws on the front panel of the XENPAK 
optical module, and gently push the XENPAK optical module in along the 
slot guide rail until the XENPAK optical module is in close contact with the 
switch. 
 

Step 4: Tighten the fastening screws on the XENPAK optical module with 
a screwdriver to fix the XENPAK optical module on the filler panel. 

 

Summary of Contents for 4200G Series

Page 1: ...t is properly grounded Then remove the XFP interface module from the package Step 2 Loosen the filler panel mounting screws on the rear panel of the switch with a screwdriver and remove the filler panel Step 3 Hold the fastening screws on the front panel of the XFP interface module and gently push the module in along the slot guide rail until the module is in close contact with the switch Step 4 T...

Page 2: ...fy it is properly grounded Step 2 Loosen the fastening screws at both sides of the XFP interface module using a screwdriver Step 3 Pull the XFP interface module towards you until it completely comes out of the switch chassis Note When installing or removing an optional interface module pay attention to the following points 1 Do not use too much force in the operation and do not touch the surface m...

Page 3: ...e filler panel with a screwdriver and remove the small cover plate Note When installing a XENPAK optical module you do not need to remove the entire filler panel Just remove the small cover plate in the middle on the filler panel Step 3 Hold the fastening screws on the front panel of the XENPAK optical module and gently push the XENPAK optical module in along the slot guide rail until the XENPAK o...

Page 4: ...he switch 4200G supports hot swapping of XENPAK optical modules 2 3 Removal Step 1 Put on an ESD preventive wrist strap and verify it is properly grounded Step 2 Loosen the fastening screws at each side of the XENPAK optical module using a screwdriver Step 3 Pull the XENPAK module until it comes out of the switch chassis Copyright 2006 3Com Corporation All rights reserved 3Com Corporation 350 Camp...

Reviews: