background image

(1) 

(2) 

(4) 

(3) 

(1) 

(2) 

(4) 

(3) 

 

(1): Switch  

(2): Optional module slot  

(3): XFP interface module  

(4): Push-in direction  

Figure 3  

Installing an XFP interface module  

Note: (1) Store the filler panel for future use.  

(2) When tightening the fastening screws at both sides of the 
optional module with a screwdriver or an electric screwdriver, 
make sure that the torque is not bigger than 0.4 N-m.  

 

1.3  Removal  

Step 1: Put on an ESD-preventive wrist strap and verify it is properly 
grounded. 
 

Step 2: Loosen the fastening screws at both sides of the XFP interface 
module using a screwdriver. 

 
Step 3: Pull the XFP interface module towards you, until it completely 
comes out of the switch chassis. 

 

Note: When installing or removing an optional interface module, pay 

attention to the following points:  

(1) Do not use too much force in the operation, and do not 
touch the surface-mounted components directly with your 
hands.  

(2) After removing an optional module, if no new module is to 
be installed, install the filler panel as soon as possible to 
prevent dust and ensure the normal ventilation in the switch.  

Summary of Contents for 4200G Series

Page 1: ...t is properly grounded Then remove the XFP interface module from the package Step 2 Loosen the filler panel mounting screws on the rear panel of the switch with a screwdriver and remove the filler panel Step 3 Hold the fastening screws on the front panel of the XFP interface module and gently push the module in along the slot guide rail until the module is in close contact with the switch Step 4 T...

Page 2: ...fy it is properly grounded Step 2 Loosen the fastening screws at both sides of the XFP interface module using a screwdriver Step 3 Pull the XFP interface module towards you until it completely comes out of the switch chassis Note When installing or removing an optional interface module pay attention to the following points 1 Do not use too much force in the operation and do not touch the surface m...

Page 3: ...e filler panel with a screwdriver and remove the small cover plate Note When installing a XENPAK optical module you do not need to remove the entire filler panel Just remove the small cover plate in the middle on the filler panel Step 3 Hold the fastening screws on the front panel of the XENPAK optical module and gently push the XENPAK optical module in along the slot guide rail until the XENPAK o...

Page 4: ...he switch 4200G supports hot swapping of XENPAK optical modules 2 3 Removal Step 1 Put on an ESD preventive wrist strap and verify it is properly grounded Step 2 Loosen the fastening screws at each side of the XENPAK optical module using a screwdriver Step 3 Pull the XENPAK module until it comes out of the switch chassis Copyright 2006 3Com Corporation All rights reserved 3Com Corporation 350 Camp...

Reviews: