A
S
PECIFICATIONS
This appendix lists the following specifications for the
Switch 4007:
■
Physical
■
Environmental
■
Power
■
Regulatory Compliance
■
Interfaces
Chassis Specifications
This section contains specifications for the
Switch 4007.
Physical
Environmental
CAUTION:
To maintain proper ventilation, keep the
sides of the Switch 4007 at least 7 cm (2.76 in.) or
greater from a wall or other obstruction. In addition,
provide at least 91.4 cm (36 inches) in back of the
switch to remove and replace the power supplies.
Height
31 cm
12.2 inches (7 Rack Units)
Width
48.3 cm
44.4 cm
19 inches (including rack-mount
flanges)
17.5 inches (not including
rack-mount flanges)
Depth
52.58 cm
20.7 inches
Weight
18.14 kg
38.55 kg
40 pounds (chassis and
backplane)
85 pounds (fully loaded)
Mounting
Tabletop, shelf, or 19-inch rack mount
Operating
temperature
1
0
°
C to 50
°
C ambient
2
(32
°
F to 122
°
F)
Operating humidity
10% to 90%, noncondensing
Storage temperature
-40
°
C to 66
°
C
(-40
°
F to 151
°
F)
Storage humidity
10% to 90%, noncondensing
1
Switch operating temperature is the temperature of the envi-
ronment in which the switch is installed.
2
Ambient air is room air (more specifically, the air drawn into
the switch by installed fans to cool installed switch compo-
nents). Ambient air temperature is
not
measured by chassis
temperature sensors.
Summary of Contents for 4007
Page 1: ...http www 3com com 3Com Switch 4007 Getting Started Guide Part No 10013650 Published May 2000...
Page 6: ......
Page 18: ...18 CHAPTER 1 ABOUT THE SWITCH 4007...
Page 28: ...28 CHAPTER 2 SWITCH 4007 MODULES...
Page 40: ...40 CHAPTER 3 INSTALLING THE SWITCH 4007...
Page 66: ...66 APPENDIX A SPECIFICATIONS...
Page 76: ...76 APPENDIX C TECHNICAL SUPPORT...
Page 84: ...84 GLOSSARY...
Page 88: ...88 INDEX...
Page 92: ......