20
C
HAPTER
2: I
NSTALLING
THE
S
WITCH
Package Contents
■
Switch unit
■
CD-ROM
■
Getting Started Guide (this guide)
■
Management Quick Reference Guide
■
Release Notes
■
Unit Information Labels
■
Warranty Information
■
Power Cord
■
2 x Mounting brackets
■
4 x Screws
■
4 x Rubber feet
Choosing a Suitable
Site
The Switch is suited for use on a desktop, either free standing or
mounted in a standard 19-inch equipment rack. Alternatively, the Switch
can be mounted in a wiring closet or equipment room, as an aggregator
for other Hubs and Switches. A rack-mounting kit containing two
mounting brackets is supplied with the Switch.
CAUTION:
Ensure that the ventilation holes are not obstructed.
When deciding where to position the Switch, ensure that:
■
Cabling is located away from:
■
sources of electrical noise such as radios, transmitters and
broadband amplifiers.
■
power lines and fluorescent lighting fixtures
■
The Switch is accessible and cables can be connected easily.
■
Water or moisture cannot enter the case of the Switch.
■
Air flow is not restricted around the Switch or through the vents in the
side of the Switch. 3Com recommends that you provide a minimum of
25mm (1in.) clearance.
■
Air temperature around the Switch does not exceed 40
°C
(104
°
F).
If the Switch is installed in a 19-inch rack or closed assembly its local air
temperature may be greater than room ambient temperature.
DUA1750-0AAA01.book Page 20 Friday, December 5, 2003 10:24 AM
Summary of Contents for 3CR17500-91
Page 6: ...DUA1750 0AAA01 book Page 6 Friday December 5 2003 10 24 AM ...
Page 50: ...50 CHAPTER 4 PROBLEM SOLVING DUA1750 0AAA01 book Page 50 Friday December 5 2003 10 24 AM ...
Page 58: ...58 APPENDIX A SAFETY INFORMATION DUA1750 0AAA01 book Page 58 Friday December 5 2003 10 24 AM ...
Page 70: ...DUA1750 0AAA01 book Page 70 Friday December 5 2003 10 24 AM ...