Solving Hardware Problems
79
Auto-negotiation problems will occur with 10BASE-T or 100BASE-T
where auto-negotiation is disabled and incorrect cables are being used
(cross-over or straight)
Auto-negotiation problems will occur with fiber if:
■
The Receiver (RX) and Transceiver (TX) cable connectors are
swapped
■
Fibers are broken
■
Auto-negotiation differs at either end (a link appears at the ‘fixed’
end and not at the auto-negotiation end)
Solving Hardware
Problems
In the rare event of your Switch unit experiencing a hardware failure,
refer to the list of suggested solutions below.
A fan failure warning message is received
Your Switch has a fan monitoring system that will generate fan failure
warning messages. Fan failure could potentially reduce the lifetime of the
Switch. The monitoring system polls the fan status at periodic intervals
while the unit is powered up.
If one fan has failed in the Switch, a warning message will be generated
in the following ways:
■
Unit LED
— the seven segment display will show a green flashing ‘f’.
■
RMON Trap
— if configured, an RMON trap is generated and sent to
the management workstation.
■
Command Line Interface
— an indication of a general hardware
failure is provided through the Top level menu displayed when logging
on to the CLI. For more detailed information about the failure select
the
display logbuffer
command.
■
Web interface
— an indication of fan failure is provided through the
Device Summary table for the specific unit. In addition all Summary
tables turn red to indicate the fan failure.
If a fan failure warning message is generated:
1
Power off the unit.
2
Check that the air vents are not obstructed.
Summary of Contents for 3CR17251-91 - Switch 5500G-EI Stackable Gigabit...
Page 8: ......
Page 48: ...48 CHAPTER 2 INSTALLING THE SWITCH...
Page 70: ...70 CHAPTER 3 SETTING UP FOR MANAGEMENT...
Page 76: ...76 CHAPTER 4 CREATING AN XRN STACKING FABRIC...
Page 84: ...84 CHAPTER 5 PROBLEM SOLVING...
Page 122: ...122 APPENDIX A SAFETY INFORMATION...
Page 126: ...126 APPENDIX B PIN OUTS...
Page 140: ...140 APPENDIX C TECHNICAL SPECIFICATIONS...
Page 148: ......