Water or moisture cannot enter the case of the Switch.
■
Air flow is not restricted around the Switch or through the vents in the
side of the Switch. 3Com recommends that you provide a minimum of
25 mm (1 in.) clearance.
■
Air temperature around the Switch does not exceed 40 °C (104
°
F).
If the Switch is installed in a 19-inch rack or closed assembly its local air
temperature may be greater than room ambient temperature.
■
The air is as free from dust as possible.
■
The Switch is situated away from sources of conductive (electrical)
dust, for example laser printers.
■
The unit is installed in a clean, air conditioned environment.
■
The AC supply used by the Switch is separate to that used by units
that generate high levels of AC noise, for example air conditioning
units.
■
No more than four Switch units are placed on top of one another, if
the units are free-standing.
Rack-mounting
The Switch 5500 is 1U high and will fit in most standard 19-inch racks.
CAUTION:
Disconnect all cables from the Switch before continuing.
Remove all self adhesive pads from the underside of the Switch if they
have been fitted.
CAUTION:
If you use a shelf or support ensure that it will not obstruct
the air flow through the side panels of the Switch.
Switch 5500 (non
PoE)
To rack-mount your Switch 5500 (non PoE):
1
Place the Switch the right way up on a hard flat surface, with the front
facing towards you.
2
Locate a securing bracket over the mounting holes on one side of the
front of the Switch, as shown in
Figure 12
.
Summary of Contents for 3CR17251-91 - Switch 5500G-EI Stackable Gigabit...
Page 8: ......
Page 48: ...48 CHAPTER 2 INSTALLING THE SWITCH...
Page 70: ...70 CHAPTER 3 SETTING UP FOR MANAGEMENT...
Page 76: ...76 CHAPTER 4 CREATING AN XRN STACKING FABRIC...
Page 84: ...84 CHAPTER 5 PROBLEM SOLVING...
Page 122: ...122 APPENDIX A SAFETY INFORMATION...
Page 126: ...126 APPENDIX B PIN OUTS...
Page 140: ...140 APPENDIX C TECHNICAL SPECIFICATIONS...
Page 148: ......