Site Requirements for the Switch 4007
33
Ventilation Requirements
This section describes ventilation requirements for the
Switch 4007. The chassis contains one fan tray that
contains four fans.
To ensure that installed fans are able to provide
adequate ventilation, maintain at least 7 cm (2.76 in.)
between the sides of the Switch 4007 chassis and the
nearest wall (or other vertical surface). Also provide at
least 91.4 cm (36 in.) behind the chassis to be able to
remove and replace power supplies in the
Switch 4007 chassis.
When you face the front of the Switch 4007 chassis,
the inlet is on the right and the exhaust is on the left.
CAUTION:
Operate a Switch 4007 chassis with four
fans running. If one fan in the fan tray fails, replace
the fan tray as soon as possible.
Power Requirements
This section list power requirements for the 930-watt
AC (Model Number 3CB9EP9) power supply.
The Switch 4007 chassis can contain two modular
930-watt power supplies. The 930-watt power
supplies provide AC power to the Switch. The
930-watt power supplies are autosensing. Each
power supply can automatically sense the type of
input voltage to which it is being connected at the
electrical outlet.
Table 5 lists power requirements for each country.
One power cord per power supply is required. The
power cord that you require depends on your country
location.
Table 6 lists the power cords for each country.
Table 6
Power Cord Description for Your Location
Table 5
Power Requirements Per Country
Location
Volts
Hz
Ampere
Asia
220 - 240 Volts
50 Hz
15-ampere
Australia
220 - 240 Volts
50 Hz
10-ampere
Canada
120 Volts
60 Hz
20-ampere
Europe
220 - 230 Volts
50 Hz
16-ampere
Japan
100 Volts
50/60 Hz
15-ampere
South Africa
220 - 250 Volts
50 Hz
16-ampere
U.K.
240 Volts
50 Hz
13-ampere
U.S.A.
120 Volts
60 Hz
20-ampere
Location
Power Cord Type
Asia
C19/AS3112
Australia
C19/AS3112 special- 10A - C19
Canada
C19/NEMA 5-20P
Europe
C19/CEE7
Japan
C19/NEMA 5-15P
South Africa
C19/SABS164
U.K.
C19/BS1363A
U.S.A.
C19/NEMA 5-2 OP
Summary of Contents for 3CGBIC97 - Switch 4007 70km Gigabit Enet Gbic
Page 1: ...http www 3com com 3Com Switch 4007 Getting Started Guide Part No 10013650 Published May 2000 ...
Page 6: ......
Page 18: ...18 CHAPTER 1 ABOUT THE SWITCH 4007 ...
Page 28: ...28 CHAPTER 2 SWITCH 4007 MODULES ...
Page 40: ...40 CHAPTER 3 INSTALLING THE SWITCH 4007 ...
Page 66: ...66 APPENDIX A SPECIFICATIONS ...
Page 76: ...76 APPENDIX C TECHNICAL SUPPORT ...
Page 84: ...84 GLOSSARY ...
Page 88: ...88 INDEX ...
Page 92: ......