mends that you provide a minimum of 25 mm or 1
in. clearance).
■
The air is as free of dust as possible.
■
Temperature operating limits are not likely to be
exceeded. It is recommended that the unit is
installed in a clean, air conditioned environment.
It is always good practice to wear an anti-static wrist
strap when installing network equipment, connected
to a ground point. If one is not available, try to keep
in contact with a grounded rack and avoid touching
the unit's ports and connectors, if possible. Static dis-
charge can cause reliability problems in your equip-
ment.
Aufstellen des Switch
Bei der Entscheidung wo Sie den Switch position-
ieren, stellen Sie sicher das:
■
Der Switch zugänglich ist und die Kabel leicht
angeschlossen werden können.
■
Die Kabel nicht in der nähe von elektrischen
Störquellen befinden. Das schließt Aufzugss-
chächte, Mikrowellen und Klimaanlagen ein. Elek-
tromagnetische Felder können die Signale in den
Kupferleitungen stören, und Fehler verursachen,
was die Verlangsamung Ihres Netzwerkes zur
Folge haben kann.
■
Weder Wasser noch Feuchtigkeit in das Gehäuse
eindringen kann.
■
Die Luftzirkulation um den Switch und durch die
Öffnungen des Gehäuses nicht behindert wird.
3Com empfiehlt das Sie 25mm (1 Inch) Zwischen-
raum sicherstellen.
■
Die Luft so frei wie möglich von Staub ist.
■
Es unwahrscheinlich ist das die Betriebstemperatur
überschritten wird. 3Com empfiehlt das Sie den
Switch in einer sauberen, klimatisierten Umgebung
installieren.
Rack-Mounting or Free-Standing
The unit can be mounted in a 19-inch equipment rack
using the supplied mounting kit, (see
), or it can be free-stand-
ing. Do not place objects on top of the unit or stack.
CAUTION:
If installing the Switch in a free-standing
stack of different size Baseline or SuperStack
®
3 units,
the smaller units must be installed above the larger
ones. Do not have a free-standing stack of more than
six units.
Using the Mounting Kit
The Switch is supplied with two mounting brackets
and four screws. These are used for rack mounting
the unit. When mounting the unit, take note of the
guidelines given in
The Switch is 1U (1.75 in.) high and will fit in a stan-
dard 19-inch rack.
CAUTION:
Before continuing, disconnect all cables
from the unit. Remove the self-adhesive pads from
the underside of unit, if already fitted.
Summary of Contents for 3C16476BS-US - Baseline 2250 Plus Switch
Page 20: ...20 CHAPTER 2 INSTALLING THE SWITCH...
Page 26: ...26 CHAPTER 3 CONNECTING TO THE WEB INTERFACE...
Page 46: ...46 CHAPTER 5 TROUBLESHOOTING...
Page 56: ...56 APPENDIX B SAFETY INFORMATION...
Page 58: ...58 APPENDIX C TECHNICAL INFORMATION...
Page 64: ...64 GLOSSARY...