TARE ZEROING PROCEDURE
Perform an empty weighing maintaining a constant raise speed. After the audible
weighing signal (weighing performed correctly) is given proceed as follows.
Press and release the
TARE pushbutton
, the displayed load will indicate zero and
press and release the ENTER pushbutton to save the new tare value. If you press the
tare function by mistake press and release the HOME pushbutton to restore the old
value.
Pressing and holding the
TARE pushbutton
for more than 5 seconds will zero the tare
value. Press and release the
UTILITY pushbutton
to change the display :
The tare value is displayed on the right side of the label. The Tare value is displayed
across from the Tare line.
Setting a New Tare
A new tare should be set when the bucket is changed or the oil changed in the
hydraulic system, or when residual material is built up in bucket. When setting a new
tare, the weight of the quantity deposited can be zeroed and only the material which
is effectively loaded into the truck is weighed.
Before beginning the loading operations the state of the tare should be checked by
performing an empty weighing; if it is not zero or close to zero. Repeat the operation
two or three times a day to compensate for the variation of temperature of the
hydraulic oil.
Tare
Disable
Count Down
Machine
Use IR
MultiProduct
Correction 100
Time Setting
Using the Remote Control and press and holding the
Total Zero switch will tare the value. To perform an
empty weighing press and hold the Tot Zero switch and
raise the boom at a constant Rpm, with the raise lever
fully open. The audible alarm will sound and then stop.
The new tare value is saved automatically.
9
Top Master
User Manual