3. Unpacking and assembly 

The microscope is packed in a molded styro-
foam container.  

 

Take the container out of the carton remove 
the tape and carefully lift the top half off the 
container. Be careful not to let the optical 
items (objectives and eyepieces) drop down. 

 

To avoid condensation on the optical com-
ponents, leave the microscope in the original 
packing to allow it to adjust to room tem-
perature.  

 

Using both hands (one around the pillar and 
one around the base), lift the microscope from 
the container and put it on a stable desk. 

 

The objectives will be found within individual 
protective vials. Install the objectives into the 
microscope nosepiece from the lowest 
magnification to the highest, in a clockwise 
direction from the rear.  

 

Put the head onto the top of the stand and 
tighten the head-lock-screw. Insert the eye-
piece into the tube. 

 

4. Operation 

4.1 General information 

 

Set the microscope on a level table. 

 

Place the object to be observed in the center 
of the object plate. Use the clips to fasten it 
into place. Make certain that the specimen is 
centered over the opening in the stage. 

 

Connect the mains cable to the net and turn 
on the switch to get the object illuminated. 

 

Make certain that the specimen is centered 
over the opening in the stage.  

 

Adjust the aperture of the iris diaphragm to 
get the background brightness suitable for a 
high contrast image. 

 

Rotate the nosepiece until the objective with 
the lowest magnification is pointed at the 
specimen. There is a definite “click” when 
each objective is lined up properly. 

NOTE: 

It is best to begin with the lowest power 

objective. This is important to reveal general 
structural details with the largest field of view 
first. Than you may increase the magnification 
as needed to reveal small details. 

To determine the magnification at which you are 
viewing a specimen, multiply the power of the 
eyepiece by the power of the objective. 

 

Adjust the coarse-focusing-knob which 
moves the stage up until the specimen is fo-
cused. Be careful that the objective does not 
make contact with the slide at any time. This 

may cause damage to the objective and/or 
crack your slide. 

 

Adjust the fine-focusing-knob to get the im-
age more sharp and more clear. 

 

Colour filters may be inserted into the filter 
holder for definition of specimen parts. 
Swing the filter holder out and insert colour 
filters. 

 

Always turn off the light immediately after 
use. 

 

Be careful not to spill any liquids on the mi-
croscope. 

 

Do not mishandle or impose unnecessary 
force on the microscope. 

 

Do not wipe the optics with your hands. 

 

Do not attempt to service the microscope 
yourself. 

 

4.2  Changing the fuse 

 

Turn off the power switch and unplug the 
mains plug. 

 

Unscrew the fuse holder on the back of the 
stand base with a screwdriver. 

 

Replace the fuse and reinsert the holder in 
its socket. 

 

5. Storage, cleaning, disposal 

 

Keep the microscope in a clean, dry and 
dust free place. 

 

When not in use always cover the micro-
scope with the dust cover. 

 

Do not expose it to temperatures below 0°C 
and above 40°C and a max. relative humid-
ity of over 85%. 

 

Always unplug the mains plug before clean-
ing or maintenance. 

 

Do not clean the unit with volatile solvents or 
abrasive cleaners. 

 

Do not disassemble objective or eyepieces 
to attempt to clean them. 

 

Use a soft linen cloth and some ethanol to 
clean the microscope.  

 

Use a soft lens tissue to clean the optics. 

 

The packaging should be disposed of at 
local recycling points. 

 

Should you need to 
dispose of the equip-
ment itself, never throw 
it away in normal do-
mestic waste. Local 
regulations for the dis-
posal of electrical 
equipment will apply. 

 

 

Summary of Contents for 200 1003266

Page 1: ...facher Vergrößerung Das Mikroskop 1003266 ist für eine Netzspan nung von 115 V 10 ausgelegt 1003267 für 230 V 10 Stativ Robustes Ganzmetallstativ Stativarm fest mit Fuß verbunden Fokussierung über beidseitig am Stativ angebrachte separate Stellknöpfe für Fein und Grobtrieb angetrieben über ein Zahnstangengetriebe mit Schwalbenschwanz verzahnung einstellbarer Anschlag zum Schutz der Objektträger un...

Page 2: ...Vergrößerung zu beginnen um zuerst größere Strukturdetails zu erkennen Der Übergang zu einer stärkeren Vergrößerung zur Betrachtung feinerer Details erfolgt durch Drehen des Revol vers bis zum gewünschten Objektiv Die Stärke der Vergrößerung ergibt sich aus dem Produkt des Vergrößerungsfaktors des Okulars und des Objektivs Mit dem Triebknopf für Grobtrieb das un scharf abgebildete Präparat scharf ...

Page 3: ...ion with a mains voltage of 115 V 10 and the 1003267 unit is for operation with 230 V 10 Stand Robust all metal stand with arm perma nently connected to the base Focussing by means of separate knobs for coarse and fine adjustment located on either side of the stand and operated by rack and pinion drive with dovetail teeth adjustable stopper for protecting the object stage and objective Tube Monocu...

Page 4: ...eneral structural details with the largest field of view first Than you may increase the magnification as needed to reveal small details To determine the magnification at which you are viewing a specimen multiply the power of the eyepiece by the power of the objective Adjust the coarse focusing knob which moves the stage up until the specimen is fo cused Be careful that the objective does not make...

Page 5: ...ines de plantes ou d animaux avec un agrandissement 40 à 400x Le microscope 1003266 est prévue pour une tension secteur de 115 V 10 et l alimenta tion 1003267 pour une tension secteur de 230 V 10 Support Bâti support entièrement métallique Grande robustesse Mise au point rapide par pignon crémaillère avec échappement fine par vis micrométrique séparée Butée de protection Tube Observation monoculai...

Page 6: ...La force d agrandissement résulte du produit du facteur d agrandissement de l oculaire et de l objectif Le bouton de mise au point rapide permet d obtenir une image nette de l objet encore flou veiller à ce que l objectif ne touche pas le support d objet risque d endommagement Ensuite régler la netteté avec la vis mi crométrique Pour utiliser des filtres de couleurs écarter le portefiltre et insér...

Page 7: ... progettato per una tensione di rete di 115 V 10 1003267 per 230 V 10 Stativo Robusto stativo completamente in me tallo braccio dello stativo fissato saldamente alla base messa a fuoco attraverso manopole per regolazione macrometrica e micrometrica separate poste ai lati dello stativo azionate me diante un ingranaggio a cremagliera con denta tura a coda di rondine battuta regolabile per la protezi...

Page 8: ...ene attraverso la rotazione del revolver fino all inserimento dell obiettivo desiderato Il valore di ingrandimento viene ottenuto dal prodotto dei fattori di ingrandi mento dell oculare e dell obiettivo Con la manopola di regolazione macrometrica mettere a fuoco il preparato ancora sfuocato prestare attenzione durante tale operazione affinché l obiettivo non vada a toccare il sup porto portaoggett...

Page 9: ...dimensionada para una tensión de red de 115 V 10 resp 1003267 para 230 V 10 Soporte Soporte de metal macizo robusto brazo soporte de incorporación fija en el pedestal Focalización por medio de botones de ajuste separados a uno y otro lado del pedestal para el accionamiento fino y burdo accionado por mecanismo de cremallera con engranaje de cola de milano tope ajustable para la protección de portao...

Page 10: ...bjetivo deseado La magnitud de la ampliación es el resultado del producto del factor de ampliación del ocular por el del objetivo Ajuste la nitidez del objeto visualizado por medio del botón de ajuste grueso pero al hacerlo tenga cuidado de que el objetivo no toque el portaobjetos Peligro de daño Ajuste a continuación la nitidez de la imagen por medio del botón de ajuste fino Si se requiere un fil...

Page 11: ...té 400 vezes O microscópio 1003266 está equipado para trabalhar com uma tensão de rede de 115 V 10 1003267 para 230 V 10 Tripé Pé de apoio robusto integralmente de metal braço de apoio fixado no pé ajuste focal por meio de botões de ajuste fino e grosseiro independentes a ambos lados do pé de apoio movidos por meio de um eixo de engrenagem de ensamblagem de encaixe limite de aproximação ajustável ...

Page 12: ... valor do grau de ampliação calcula se a partir do produto do fator de aumento do ocular e da objetiva Ajustar o foco da imagem desfocada da preparação utilizando o botão rotativo para ajuste grosseiro Ao faze lo tomar cuidado para que a objetiva não esbarre no porta objeto perigo de danificação Logo efetuar o ajuste de foco final com o ajuste fino Para utilizar filtros cromáticos girar o porta fi...

Reviews: