container. Be careful not to let the optical 
items (objectives and eyepieces) drop down. 

 

To avoid condensation on the optical com-
ponents, leave the microscope in the original 
packing to allow it to adjust to room tem-
perature. 

 

Using both hands (one around the pillar and 
one around the base), lift the microscope 
from the container and put it on a stable 
desk. 

The microscope is fully assembled except for 
the eye-shields. Position them over the eye-
pieces for viewing comfort and to block out any 
ambient light. In addition, the object plate must 
be inserted into the stage opening in the base.  

 

 

3. Operation 

3.1 General information 

 

Set the microscope on a level table. 

 

Place the object to be observed in the center 
of the object plate. Use the clips to fasten it 
into place. 

 

Connect the mains adaptor, and switch on 
the illumination.  

Alternatively, the microscope can also be oper-
ated without being connected to the mains. 

 

When using transmitted light illumination 
replace black and white plate with the glass 
plate. 

 

On the toggle switch position I is for trans-
mitted light and position II is for top-light. 

 

Adjust the interpupillary distance between 
the eyepieces by grasping the two prism-
housings with both hands and moving them 
until one circle of light can be seen. 

 

Focus the object by turning the side knobs. 

 

It might be necessary to loosen the lock-
screw and raise or lower the entire stereo 
head-bracket until the outline of the object is 
found in the field of view. 

 

Be sure to tighten the lock-screw to fix the 
height of the stereo head on the pillar. 

 

Always turn off the light immediately after 
use. 

 

Be careful not to spill any liquids on the mi-
croscope. 

 

Do not mishandle or impose unnecessary 
force on the microscope. 

 

Do not wipe the optics with your hands. 

 

Do not attempt to service the microscope 
yourself. 

 

3.2  Changing the objective 

 

Loosen the lock-screw on the objective 
mount with a small screwdriver and pull out 
the objective assembly horizontally. 

 

Insert an alternate objective by sliding it into 
the objective mount. 

 

Secure it by tightening the lock-screw. 

 

 

4. Storage, cleaning, disposal 

 

Keep the microscope in a clean, dry and 
dust free place. 

 

When not in use always cover the micro-
scope with the dust cover. 

 

Do not expose it to temperatures below 0°C 
and above 40°C and a max. relative humid-
ity of over 85%. 

 

Always unplug the mains plug before clean-
ing or maintenance. 

 

Do not clean the unit with volatile solvents or 
abrasive cleaners. 

 

Do not disassemble objective or eyepieces 
to attempt to clean them. 

 

Use a soft linen cloth and some ethanol to 
clean the microscope.  

 

Use a soft lens tissue to clean the optics. 

 

The packaging should be disposed of at 
local recycling points. 

 

Should you need to 
dispose of the equip-
ment itself, never throw 
it away in normal do-
mestic waste. Local 
regulations for the dis-
posal of electrical 
equipment will apply. 

 

 

Do not dispose of the battery in the regular 
household garbage. Follow the local regula-
tions (In Germany: BattG; EU: 2006/66/EG). 

 

 

Summary of Contents for 1005442

Page 1: ...bknöpfe Tubus Stereokopf mit Schrägeinblick 45 Au genabstand zwischen 55 mm und 75 mm ein stellbar Okulare Weitfeld Okularpaar WF 10x 20 mm mit Okularsicherung Dioptrienausgleich 5 am linken Okular Gummi Augenmuscheln Objektiv Objektiv 2x mit Schlittenführung und Schnellwechseleinrichtung Vergrößerung 20x Objektscheibe Fuß mit herausnehmbarer Ob jektscheibe Kunststoff schwarz weiß und Glas 95 mm Ø...

Page 2: ...or nehmen Nach Gebrauch sofort die Beleuchtung aus schalten Das Mikroskop mit keinen Flüssigkeiten in Kontakt kommen lassen Das Mikroskop keinen mechanischen Belas tungen aussetzen Optische Teile des Mikroskops nicht mit den Fingern berühren Bei Beschädigungen oder Fehlern das Mik roskop nicht selbst reparieren 3 2 Objektivwechsel Seitliche Schraube am Objektivgehäuse mit einem kleinen Schraubenzi...

Page 3: ...for coarse and fine focusing Tube Binocular inclined 45 interocular dis tance adjustable between 55 and 75 mm Eyepieces Pair of wide field eyepieces WF 10x 20 mm with eyepiece lock and rubber eyepiece cups diopter compensation 5 on the left eye piece Objectives Lens 2x with slide and quick change device Enlargement 20x Object Plate Base with detachable object plates plastic black white and glass 9...

Page 4: ...be necessary to loosen the lock screw and raise or lower the entire stereo head bracket until the outline of the object is found in the field of view Be sure to tighten the lock screw to fix the height of the stereo head on the pillar Always turn off the light immediately after use Be careful not to spill any liquids on the mi croscope Do not mishandle or impose unnecessary force on the microscope...

Page 5: ...de 230 V 10 Support Support métallique hauteur ajustable sur colonne mise au point par commande bila térale crémaillère de précision Tube Observation binoculaire inclinée à 45 écartement interpupillaire réglable entre 55 et 75 mm Oculaire Paire d oculaires grand champ WF 10x 20 mm fixés par vis et œilletons en caout chouc avec ajustement dioptrique 5 sur le porte oculaire gauche Objectifs Bloc obj...

Page 6: ...oin desserrer la vis de fixation de la colonne de la potence et procéder au régla ge rapide en montant ou en abaissant l optique complète Après l utilisation du microscope éteindre immédiatement l éclairage Le microscope ne doit jamais entrer en con tact avec des liquides Ne jamais exposer le microscope à des contraintes mécaniques Ne pas toucher les parties optiques du mi croscope avec les doigts...

Page 7: ...le due manopole sullo stativo Tubo Visione binoculare inclinata a 45 distan za tra gli occhi regolabile 55 75 mm Oculari Coppia di oculari grande campo WF 10x 20 mm con protezione oculare compensa zione diottrie 5 sull oculare sinistro mascherine in gomma Obiettivi Obiettivo 2x con guide a slitta e di spositivo di cambio rapido Ingrandimento 20x Tavolino portaoggetti Piede con disco estrai bile in...

Page 8: ...o stativo ed effettuare la regolazione macrometrica sollevando o abbassando l intera ottica Dopo l uso spegnere immediatamente la lampada Il microscopio non deve entrare in contatto con sostanze liquide Non sottoporre il microscopio a sollecitazioni meccaniche Non toccare con le dita le parti ottiche del microscopio In caso di danneggiamento o di difetti del microscopio non cercare di effettuare l...

Page 9: ... de ajuste situados en ambos lados del soporte Tubo Visión oblicua binocular 45 distancia entre los ojos ajustable entre 55 y 75 mm Ocular Par de oculares de campo amplio WF 10x 20 mm con seguro del ocular anteojeras de goma corrección de dioptría 5 Objetivo Objetivo 2x con guía de carro y dispositivo de cambio rápido Magnificación 20x Portaobjetos Base con disco de quita y pon de plástico negro b...

Page 10: ...ice el ajuste grueso elevando o bajando la óptica completa Tras el uso desconecte inmediatamente la iluminación El microscopio no debe entrar en contacto con ningún tipo de líquido El microscopio no debe ser sometido a ningún tipo de carga mecánica No tocar con los dedos las piezas ópticas del microscopio En caso de daños o de que el microscopio presentara fallos no trate de repararlo Ud mismo 3 2...

Page 11: ...te colocados em ambos lados do tripé Tubo Binocular oblíquo 45 distância entre os olhos ajustável entre 55 e 75 mm Oculares Par de oculares grande angular WF 10x 20 mm com seguro ocular um ocular com compensação de dioptria de 5 apoio de bor racha para o olho Objetiva Objetiva 2x com cursor de guiamento e dispositivo de troca rápida Aumentos 20x Platina porta objeto Pé de apoio com lâmina móvel pa...

Page 12: ...e efetue o ajuste ótico grosseiro completo levantando ou de scendo Desligue a iluminação imediatamente após cada utilização O microscópio jamais deve entrar em contato com qualquer líquido Não exercer qualquer pressão mecânica sobre o microscópio Nunca toque com os dedos nas partes óticas do microscópio Em caso de danificação ou defeito do microscópio não o conserte por si mesmo 3 2 Troca de objet...

Reviews: