background image

 

Associated Equipment needed 

 
1).Mixer

 PF300A12DAASS (for channel 12) 

The Mixer should be installed near the Camera at the

 

surveillance site 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

2).Mixer

 PF300A12DASS (for channel 1 –11) 

The Mixer should be installed near the Camera at the

 

surveillance site 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

   Thickness
35mm(1-3/8in)

96mm(3-3/4in)

70mm
(2-3/4in)

PF300A12DAASS

70mm
(2-3/4in)

   Thickness

35mm(1-3/8in)

96mm(3-3/4in)

PF300A12DASS

Summary of Contents for CI-12-ASP-DAASS

Page 1: ...1 CCTV INSTALLTION SYSTEM 12 CHANNELS Signal Processor for transmission of Power Video Two Way Audio Control Data and Two Way Security Fire Alarm Signals Signal Processor CI 12 ASP DAASS User Manual ...

Page 2: ...r complete CCTV System Associated Equipment Mixer PF300A12DAASS Mixer PF300A12DASS DB 4RJ Distribution Board for Four Cameras star connection with RJ45 Sockets CC 2RJ Distribution Board for Four Cameras ring connection with RJ45 Socket PS 10KU Power Stabilizer RM 16 Mounting Bracket For instructions regarding the connection of the associated equipment in your system please consult the User Manual ...

Page 3: ...Stabilizer 4 4 5 5 5 6 6 6 6 Cat 5 Cable Application Specification CI 12 ASP PVDAASS Typical Wiring 1 Wiring Connections for Channel 1 to Channel 11 with ONE Cat5 cable for one camera 6 7 8 15 8 9 2 Wiring Connections for Channel 12 with Cat5 cable 3 Wiring Connections of one CAT 5 for four cameras Star method 4 Wiring Connections of one CAT 5 for four cameras Ring method 10 11 12 13 14 15 How to ...

Page 4: ...era side CONTROL DATA for camera and TWO WAY ALARM Signals In this case the suitable Mixer should be PF300A12DASS The channel 12 is able to transmit POWER VIDEO TWO WAY AUDIO CONTROL DATA for moving the camera and TWO WAY ALARM signals The Mixer should use PF300A12DAASS 2 POWER CORD AU AUSTRALIA BS HONG KONG and UK CN CHINA EU EUROPEAN countries please specific the country US only for US market CI...

Page 5: ...e installed near the Camera at the surveillance site 2 Mixer PF300A12DASS for channel 1 11 The Mixer should be installed near the Camera at the surveillance site Thickness 35mm 1 3 8in 96mm 3 3 4in 70mm 2 3 4in PF300A12DAASS 70mm 2 3 4in Thickness 35mm 1 3 8in 96mm 3 3 4in PF300A12DASS ...

Page 6: ... 485 Cat 5 Cable Application The Cable connecting RJ45 connector for Mixer to Signal Processor with Cat5 is as follows To achieve best performance of the 2Y LINK System the main points for standard Cat 5 cable must be noted as follows 1 DC resistance 10 Ohm 100m 330ft 2 For Cat 5 cable wiring connection RJ45 connector should be used according to usual computer network standard TIA EIA 568 B as bel...

Page 7: ...meras Power Video Audio data RS485 and Alarm I O between SP and Mixer RJ45 Sockets One Cat 5 cable for 4 Cameras Data RS485 Input from Control Keypad RJ45 Sockets Alarm Input Output Terminal Back Video Output to DVR Monitor BNC Plug Audio Output to DVR BNC Plug Audio Output to Active Speakers Terminal Data RS485 Input from Control Keypad Terminal Microphone Input Terminal Power IN from AC DC adapt...

Page 8: ... 11 with ONE Cat5 cable for one camera HIGH POWER and LONG Transmission Camera power distance table Camera power 12V DC 100 1200 mA 1 2 14 4 W 1200 1500mA 14 4 18 W 1500 2000mA 18 24W Distance 500m 1640ft 400m 1312ft 300m 980ft Surveillance Site Mixer PF300A12DASS ...

Page 9: ...9 Typical Wiring Control Room C01 C11 AC Power In Signal Processor CI 12 ASP DAASS ...

Page 10: ...for one camera HIGH POWER and LONG Transmission Camera power distance table Camera power 12V DC 100 1000 mA 1 2 12 W 1000 1300mA 12 15 6 W 1300 1600mA 15 6 19 2W 1600 2000mA 19 2 24W Distance 500m 1640ft 400m 1312ft 300m 980ft 200m 650ft Mixer PF300A12DAASS Surveillance Site ...

Page 11: ...11 Typical Wiring C12 Signal Processor CI 12 ASP DAASS AC Power In Control Room ...

Page 12: ...g 3 Wiring connections of one CAT 5 for four cameras Star method Mixers in star connection Surveillance Site Power stabilizer DB 4RJ PTZ Camera 8W Power To 500mA Terminal Video Data Camera 6W Camera 6W Power stabilizer ...

Page 13: ...ing Camera power distance table Camera power 12V DC 100 250 mA 1 2 3 W 250 400mA 3 4 8 W 400 500mA 4 8 6 W Distance 500m 1640ft 350m 1150ft 150m 490ft Control Room Signal Processor CI 12 ASP DAASS AC Power In C01 C04 ...

Page 14: ...ng method Mixers in ring connection Surveillance Site PTZ Camera 6W Power To 500mA Terminal Video Video Power To 500mA Terminal PTZ Camera 6W PTZ Camera 6W Power To 500mA Terminal Video Power To 500mA Terminal Fire Alarm Fire Alarm Fire Alarm To S P To other zone To Mixer ...

Page 15: ...ring Camera power distance table Camera power 12V DC 100 250 mA 1 2 3 W 250 400mA 3 4 8W 400 500mA 4 8 6W Distance 500m 1640ft 350m 1150ft 150m 490ft C01 C04 Control Room AC Power In Signal Processor CI 12 ASP DAASS ...

Page 16: ...16 RM 16 a pair How to mount the Signal Processor to 19 rack RM 16 a pair ...

Page 17: ... 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 SHARPNESS BRIGHTNESS BRIGHTNESS SHARPNESS SWITCH C03 C04 C05 C06 C01 C02 C07 C08 C09 C10 C11 C12 7 6 Video Power Audio Alarm DATA RJ45 sockets Video Green LED ON Audio Yellow LED ON Power LED Indicator Fan 2 3 5 4 1 Power C07 C01 C11 C12 C10 C09 C08 C07 C06 C05 C01 C02 C04 C03 Item Icon Description Usage or Pu...

Page 18: ...per channel Alarm Output Terminals For connecting to Data Control unit with Bell Cable for controlling PTZ Camera at Mixer side RS485 from Data controller I O Terminals 15 Connecting AC Power Cord to the Socket with built in 5A Fuse AC Power ON OFF Switch To indicate that the power switch is on and the AC power fuse and AC power cord are in proper working condition For connecting to DVR or CCTV Mo...

Page 19: ... for controlling the movement of PTZ Camera Microphone Terminals 2Y LINK Mixer Microphone PVA MIC or Microphone with Output impedance 600 3000 Ohm and DC operating voltage 9 15 Volt For connecting to 8 Ohm speaker AUDIO OUT Terminals Detail Overview Mixer PF300A12DAASS For Transmission of Power Video Control Data Two way Audio Two way Alarm signals ...

Page 20: ...ating DC12V up to 2A To indicate that the AC DC adaptor is in proper working order Alarm output 12V 50mA showing a triggering signal from signal processor For Connecting the security Fire alarm units at triggering state of signal processor the units are in close status For connections to Signal Processor transmission of Power Video and Data Signals using Cat 5 Cable Detail Overview Mixer PF300A12D...

Page 21: ...o Camera rating DC12V up to 500mA 2Y LINK Mixer Microphone PVA MIC or Microphone with Output impedance 600 3000 Ohm and DC operating voltage 9 15 Volt Microphone Terminals Connecting to terminals of PTZ Camera for controlling the movement of PTZ Camera RS485 I O Terminal For connecting to Camera Video In BNC plug Usage or Purpose Description Icon Item 1 4 3 2 ...

Page 22: ... showing a triggering signal from signal processor Connecting Stabilizer PS 10KU for Power Stabilization To indicate that the AC DC adaptor is in proper working order Connecting to Camera rating DC12V up to 2A Usage or Purpose Description Icon Item 5 8 9 7 6 10 Power LED Indicator PS 10KU Socket Power Video and Data RJ45 Sockets Alarm Input Terminals Alarm Output Terminals DC Power to Camera Termi...

Page 23: ...e or socket is not properly connected to the DVR or Monitor 5 The monitor screen shows unsteady pictures when the control keypad is in operation Insufficient line current supply to the PTZ camera To fit a Power Stabilizer PS 10KU to the Mixer 6 There is no movement of the PTZ Camera when the control keypad is in operation PTZ camera doesn t receive any control data signal from signal processor Con...

Page 24: ...nance or modification ii parts or supplies not provided or supported iii operation outside the product s specifications or iv unauthorized modification or misuse SHALL NOT BE LIABLE FOR THE LOSS OR DESTRUCTION OF VIDEO IMAGE OR DATA RESULTING FROM THE USE OR SERVICE OF THIS PRODUCT WHETHER DUE TO VIRUS ISSUES OR OTHERWISE OR ANY FAILURE TO SECURE ALL VIDEO IMAGE AND DATA TRANSMITTED OR AFFECTED BY...