background image

16

VSES2C100-E1AC-ZP-xxx

VSES2C100-V1,S0AC-ZP-xxx

10. WIRING DIAGRAM

Summary of Contents for Essensse Neo VCES2-B Series

Page 1: ...ESSENSSE NEO VCES2 B xx VCES2 C xx EN INSTALLATION 4 118 0246 P01 0215 0517 00 ...

Page 2: ...and information Detailed technical information Reference to another part of the manual This manual includes important instructions for the appropriate installation of the air curtains Before installing read carefully all the following instructions and observe them The manufacturer reserves the right to change including the technical documentation without prior notice Keep the manual for future use...

Page 3: ...r After unpacking check that the product and all the other components are in good order In case of doubt contact the vendor Do not install a damaged unit If you will not unpack the product immediately after delive ry store it indoors in a dry place with ambient temperatu res between 5 C and 40 C 2 2 CONTENTS 5 o C 40 o C All the packaging material is environ mentally friendly and can be reused or ...

Page 4: ...0 S 31 3 VCES2C 150 S 35 7 VCES2B 200 S 38 3 VCES2C 200 S 45 8 VCES2B 250 S 45 1 VCES2C 250 S 53 1 A I 8 H G E F B C 15 15 J D TYPE A B C D E F G H I J mm mm mm mm mm mm mm mm mm mm VCES2B 100 913 1190 377 252 51 111 90 211 67 3 4 VCES2C 100 913 1190 377 252 51 111 90 211 67 3 4 VCES2B 150 1321 1600 377 252 51 111 90 211 67 3 4 VCES2C 150 1321 1600 377 252 51 111 90 211 67 3 4 VCES2B 200 1822 2100...

Page 5: ...B 100 V 16 9 0 7 161 0 7 50 60 VCES2B 150 V 24 7 1 230 1 50 60 VCES2B 200 V 35 7 1 3 299 1 3 50 60 VCES2B 250 V 43 3 1 6 370 1 6 50 60 VCES2B 100 S 0 7 161 0 7 50 60 VCES2B 150 S 1 230 1 50 60 VCES2B 200 S 1 3 299 1 3 50 60 VCES2B 250 S 1 6 370 1 6 50 60 VCES2C 100 E1 5 9 9 15 4 370 1 6 230 50 60 VCES2C 150 E1 7 9 15 2 23 8 460 2 50 60 VCES2C 200 E1 10 2 19 1 30 7 690 3 50 60 VCES2C 250 E1 12 9 25...

Page 6: ...t with regards to the regula tions applicable at the place of installation the unit may be installed only in horizontal position there must be at least 200 mm of free space in front of the suction cover for the proper functioning of the unit the exhaust should be located as near as possible to the door or the curtain opening the curtain should extend beyond both sides of the open ing by at least 1...

Page 7: ...all according to the following figures 1 Fastening to the ceiling 2 Fastening to the curtain 10mm 30mm 4x 30mm 10mm hanging from threaded rods Installation with threaded rods YOU WILL NEED 4 6mm anchors not included 4 M6 threaded rods not included 8 M6 nuts not included M10 spanner not included ...

Page 8: ... Tighten the terminal box with the help of the tool Tensioning the terminal block using the siko tongs 6 4 Installing the control module detailed instructions can be found in the respective manual The following procedure requires the removal of the suction cover 6 4 1 remove the design sideboard fas tened with two M5 screws on the side of the motor 3mm ...

Page 9: ... above it is advisable to install a shut off valve at the inlet and the outlet of the heater to interrupt the water supply 2 Insert and fasten the regulator s terminal box to the cur tain s terminal box with the supplied tool or with Siko pliers 3 Tighten all the screws of the module 4 Fasten the regulator with a screw see figure below TECHNICAL INFORMATION The tool to install the module is suppli...

Page 10: ...is properly connected During the commissioning check the proper function of the unit fans heating Check the other possible settings and functions according to the user manual of each regulator 7 COMMISSIONING 7 1 SETTING THE DIRECTION OF THE EX HAUST AIR CAUTION Deflect the exhaust in the desired direction during the instal lation of the unit The exhausts of the Essensse air curtain can blow air a...

Page 11: ...er serial number running time used accessories installation location installation condition including electrical detailed description of the problem and the steps that you have taken for its removal Warranty and post warranty service is performed by the manufacturer supplier or authorized service organizati on When ordering service intervention it is necessary to describe the defect product type d...

Page 12: ...12 10 WIRING DIAGRAM VSES2B100 E1AC ZP xxx VSES2B100 V1 S0AC ZP xxx ...

Page 13: ...13 VSES2B150 E1AC ZP xxx 10 WIRING DIAGRAMS VSES2B150 V1 S0AC ZP xxx ...

Page 14: ...14 VSES2B200 E1AC ZP xxx VSES2B200 V1 S0AC ZP xxx 10 WIRING DIAGRAM ...

Page 15: ...15 VSES2B250 E1AC ZP xxx VSES2B250 V1 S0AC ZP xxx 10 WIRING DIAGRAMS ...

Page 16: ...16 VSES2C100 E1AC ZP xxx VSES2C100 V1 S0AC ZP xxx 10 WIRING DIAGRAM ...

Page 17: ...17 VSES2C150 E1AC ZP xxx VSES2C150 V1 S0AC ZP xxx 10 WIRING DIAGRAMS ...

Page 18: ...18 VSES2C200 E1AC ZP xxx VSES2C200 V1 S0AC ZP xxx 10 WIRING DIAGRAM ...

Page 19: ...19 VSES2C250 E1AC ZP xxx VSES2C250 V1 S0AC ZP xxx 10 WIRING DIAGRAMS ...

Page 20: ...he Manual for the appropriate regulator In case of any doubt or query do not hesitate to contact our sales or technical support departments CONTACT Address 2VV s r o Poděbradská 289 530 09 Pardubice Česká republika Internet http www 2vv cz 11 CONCLUSION ...

Reviews: