2N TELEKOMUNIKACE a.s., www.2n.cz
15/72
1.
Caution
The warranty does not apply to the product defects and failures arisen
as a result of improper mounting (in contradiction herewith). The
manufacturer is neither liable for damages caused by theft within an
area that is accessible after the attached electric lock is switched. The
product is not designed as a burglar protection device except when
used in combination with a standard lock, which has the security
function.
When the proper mounting instructions are not met, water might get in
and destroy the electronics. It is because the intercom circuits are under
continuous voltage and water infiltration causes an electro-chemical
reaction. The manufacturer's warranty shall be void for products
damaged in this way!
Note
The microphone sound guides are normally loose after the front panel is
removed! The screw is only used as a fall-out protection during
installation.
Flush Mounting – Classic Bricks
If you use the brick flush mounting box, follow the instructions included in the box. If
you do not use the mounting box, follow the instructions below:
What You Need:
A precisely cut hole or, optionally, the brick flush mounting box, Part No. 9151001
Hole: (132 × 223 × 83) mm (with flush mounting box)
Hole: (112 × 220 × 70) mm (without flush mounting box)
Make a hole using the template. Suppose that all the required cables have been
carried into the hole.