Dear customer, congratulation on your purchase of the 2N APS mini 

EntryCom

 set. It is  

our 

wish  that  you  are  fully  satisfied  with  this  product  for  a  long  time.  Because  it  is  a  

product,  which  is  being  constantly  improved,  any  comments  and  proposals  leading  to  a 

better product are very welcome. 

 

Module characteristics 

Reading  module  for  identification  of  chip  cards  2N  APS  mini 

EntryCom

  set  is  designed  

for 

simple applications of access management and recording attendance using chip cards.  

It 

consists of a mother board and a reading antenna, which serves for non-contact reading of 

chip cards codes. It is designed to be installed into the door communicator 

2N EntryCom

 

and therefore it enables adding the function of chip card reader to the door communicator. 

 

Brief description of the system 

System APS mini is designed for management of access and recording of attendance in 

objects  with  up  to  748  users.  Identification  of  persons  is  provided  by  non-contact  chip 

cards and key rings. Its basic features include: low price, easy installation, high reliability 

and minimum service and maintenance requirements. 
The basic functions of the system, managing access and programming access rights, are 

carried out by the reading module autonomously – without the need to be connected to the 

PC. After connecting to the PC the system offers more functions – thanks to online status 

monitoring and to archiving of events from the connected reading modules. 
The reading module integrating all circuits necessary for one reading place and one door 

is the basic hardware element of the APS mini access system. 

 

Regimes of operation 

Autonomous  …  programming  of  the  database  of  access  rights  is  carried  out  via 

programming cards (“adding” and “deleting”). 
Offline … programming of the database of access rights is carried out via PC. It is also 

possible to configure operational parameters of the reading module. 
Online  …  PC  constantly  communicates  with  the  reading  module  or  system  of  reading 

modules (up to 32 modules) and stores all events in the system’s archive. 

Reading module ATEUS 

®

 - APS mini can be used in all regimes of operation. Standard 

accessories  to  the  module  include  2  programming  cards  for  adding  and  removing  user 

cards without the need to connect the reading module to the PC (autonomous regime). 
Software for operating the reading module via the PC in offline and online regimes can be 

downloaded free of charge from the producer’s website 

www.2n.cz

. Communication with 

the  reading  modules  via  the  PC  requires  installation  of  communication  converter 

RS485/PC  to  the  communication  line  (converter  RS485/RS232,  RS485/USB  or 

RS485/Ethernet). 

 

Summary of Contents for APS MINI ENTRYCOM

Page 1: ...2N APS MINI ENTRYCOM SET Order No 91341611WE User and service manual Version 2 1...

Page 2: ...E EntryCom Set 9134162WE Standalone reader module 9134167WE Reader module with attendance keypad 91341612WE Built in reader module for EntryCom 91341631E Converter RS485 Ethernet 9134164E PC mini read...

Page 3: ...t by the reading module autonomously without the need to be connected to the PC After connecting to the PC the system offers more functions thanks to online status monitoring and to archiving of event...

Page 4: ...cess cards in the memory 748 Inputs 2x logical non potential Output for door lock 1x relay switch contact 2 A 24 V Alarm output Transistor output 5 V 5 mA Protective contact tamper Opto electric Typic...

Page 5: ...bjects absorb electromagnetic field and may disturb the antenna of the module also in this case we recommend practical test It is recommended to install the chip card reader indoor on a wall together...

Page 6: ...tage use contacts C and NO For locks that open when voltage disappears while under voltage they are locked use contacts C and NC Lead voltage through these contacts from the power supply to the door l...

Page 7: ...end of the data bus last module on the line must contain terminal resistor jumper inserted on the contacts of the J5 connection When using certain converters dividers and repeaters on the RS485 data...

Page 8: ...proper connection of the module Area for setting the HW address Area with control elements for setting the general properties of the module Indicators are located in the individual parts of the status...

Page 9: ...to the normal operational regime by itself Erasing cards from the memory Step 1 Step 2 Step 3 After having read the programming card for erasing the reader is set to programming regime Read cards that...

Page 10: ...2N TELEKOMUNIKACE a s Mod ansk 621 143 01 Praha 4 Czech Republic tel 420 261 301 111 fax 420 261 301 999 e mail sales 2n cz www 2n cz 2008 2N TELEKOMUNIKACE a s Praha OV 1350 v 2 1...