background image

 

Setting parameters and access rights using the PC 

 Setup  program  APS  mini  Reader  is 

designed  for  operating  system  Windows 

95,  Windows  NT  4.0  and  higher,  it  does 

not require installation. It is designed for 

offline  regime  of  readers  and  it  allows 

programming  operational  parameters  on 

the  individual  2N  APS  mini  modules 

connected  via  data  bus  RS485.  It  does 

not  allow  programming  access  rights. 

Connection  of  modules  to  the  PC 

requires  either  communication  converter 

RS485/RS232  (or  RS485/USB)  with 

automatic  switching  of  the  direction  of 

communication 

or 

converter 

RS485/Ethernet,  with  settings:  8  data 

bits, even parity, 19 200 bits per second, 

1 stop bit. 

 

Main menu of the program contains the following commands: 

  Program   Settings … displays settings dialogue for the communication port of the PC 

and code of the service card, 

  Start / Stop … controlling communication with the module, 

  Write … saves the configuration of general properties of the reading module, 

  Program   End … ending the program. 

 

Workspace of the program is divided into 3 parts: 

  Area for visualization of the status of the reading module (to be used for verification of 

proper connection of the module), 

  Area for setting the HW address, 

  Area with control elements for setting the general properties of the module. 

 

Indicators are located in the individual parts of the status bar (from the left): 

  Indicator  of  the  state  of  communication  with  the  module  (red  color  indicates  error  in 

communication, flawless communication is indicated by green color), 

  Indicator of the process of saving operational parameters, 

  Verbal description of the state of communication.  

Setting the operational parameters defined in the corresponding input fields is carried out 

after communication was established and after the button “Write” was pressed. The setup 

program  communicates  always  with  one  module  (module  with  address  specified  in  the 

field “HW Address”). Result of the action is shown by the progress indicator in the second 

part of the status bar.

 

Modules  2N  APS  mini  in  the  online  regime  can  be  controlled  via  programs  APS  mini 

Administrator, APS mini Events and APS mini ED. These allow, besides programming the 

parameters of the modules, also setting access rights and monitoring various events (for 

example  arriving  and  leaving  persons)  and  analyze  them.  The  programs  can  be 

downloaded free of charge from the manufacturer’s website 

www.2n.cz

Visualization  of 

states 

 

Setting 

general 

parameters

 

Setting 

the 

HW address

 

 

Summary of Contents for APS MINI ENTRYCOM

Page 1: ...2N APS MINI ENTRYCOM SET Order No 91341611WE User and service manual Version 2 1...

Page 2: ...E EntryCom Set 9134162WE Standalone reader module 9134167WE Reader module with attendance keypad 91341612WE Built in reader module for EntryCom 91341631E Converter RS485 Ethernet 9134164E PC mini read...

Page 3: ...t by the reading module autonomously without the need to be connected to the PC After connecting to the PC the system offers more functions thanks to online status monitoring and to archiving of event...

Page 4: ...cess cards in the memory 748 Inputs 2x logical non potential Output for door lock 1x relay switch contact 2 A 24 V Alarm output Transistor output 5 V 5 mA Protective contact tamper Opto electric Typic...

Page 5: ...bjects absorb electromagnetic field and may disturb the antenna of the module also in this case we recommend practical test It is recommended to install the chip card reader indoor on a wall together...

Page 6: ...tage use contacts C and NO For locks that open when voltage disappears while under voltage they are locked use contacts C and NC Lead voltage through these contacts from the power supply to the door l...

Page 7: ...end of the data bus last module on the line must contain terminal resistor jumper inserted on the contacts of the J5 connection When using certain converters dividers and repeaters on the RS485 data...

Page 8: ...proper connection of the module Area for setting the HW address Area with control elements for setting the general properties of the module Indicators are located in the individual parts of the status...

Page 9: ...to the normal operational regime by itself Erasing cards from the memory Step 1 Step 2 Step 3 After having read the programming card for erasing the reader is set to programming regime Read cards that...

Page 10: ...2N TELEKOMUNIKACE a s Mod ansk 621 143 01 Praha 4 Czech Republic tel 420 261 301 111 fax 420 261 301 999 e mail sales 2n cz www 2n cz 2008 2N TELEKOMUNIKACE a s Praha OV 1350 v 2 1...

Reviews: