background image

Overview of module’s features in various regimes of operation 

Function 

Regime of operation 

 

autonomous  offline  online 

Definition of access rights using programming cards 

 

 

 

Signalization of reading a card and releasing the door lock 

 

 

 

Acoustic signalization of alarm situations 

 

 

 

Changing the parameters of regimes of operation and alarm 

regimes 

 

 

 

Definition of access rights from the PC 

 

 

 

Visualization  of  the  regime  of  the  reading  module,  recording 

events in an archive in the PC, viewing and working with events 

 

 

 

Controlling the output of the reading module directly from the PC 

 

 

 

 

Technical parameters 

Dimensions of the mother board 

81 x 81 x 25 mm 

Power supply 

10 

÷

 15 VDC 

Max. power input 

160 mA 

ID technology 

EM Marin, 125kHz 

Max. number of access cards in the memory 

748 

Inputs 

2x logical, non-potential 

Output for door lock 

1x relay switch contact 2 A / 24 V 

Alarm output 

Transistor output 5 V / 5 mA 

Protective contact (tamper) 

Opto-electric 

Typical reading distance 

2 cm (in panel) 

Communication channel 

RS485 galvanic non-separated 

Alternative data output 

WIEGAND (configurable) 

Signalization 

Piezzo- 3x LED (on the board) 

Working temperature 

-10 

÷

 +40°C 

Max. relative humidity 

75%, without condensation 

 

Configurable operational parameters 

Parameter 

Possible values 

Default value 

Lock release duration 

÷

 255 s 

7 s 

Acoustic signalization of lock releasing 

Yes / no 

Yes 

Maximum duration of door opening 

÷

 255 s 

30 s 

Duration of acoustic signalization of violation 

÷

 255 s 

30 s 

Duration of acoustic signalization of door broken open 

÷

 255 s 

30 s 

Duration of acoustic signalization of door open too long  0 

÷

 255 s 

0 s 

Function of the 2

nd

 input 

Leaving button / 
handle contact 

Leaving button 

Summary of Contents for 91341611WE

Page 1: ...2N APS MINI ENTRYCOM SET Order No 91341611WE User and service manual Version 2 1 ...

Page 2: ...WE EntryCom Set 9134162WE Standalone reader module 9134167WE Reader module with attendance keypad 91341612WE Built in reader module for EntryCom 91341631E Converter RS485 Ethernet 9134164E PC mini reader 9134165E Chip card 9134166E Chip key fob ...

Page 3: ...ut by the reading module autonomously without the need to be connected to the PC After connecting to the PC the system offers more functions thanks to online status monitoring and to archiving of events from the connected reading modules The reading module integrating all circuits necessary for one reading place and one door is the basic hardware element of the APS mini access system Regimes of op...

Page 4: ...ccess cards in the memory 748 Inputs 2x logical non potential Output for door lock 1x relay switch contact 2 A 24 V Alarm output Transistor output 5 V 5 mA Protective contact tamper Opto electric Typical reading distance 2 cm in panel Communication channel RS485 galvanic non separated Alternative data output WIEGAND configurable Signalization Piezzo buzzer 3x LED on the board Working temperature 1...

Page 5: ...objects absorb electromagnetic field and may disturb the antenna of the module also in this case we recommend practical test It is recommended to install the chip card reader indoor on a wall together with the door communicator and reader s antenna Installing the reader indoors will provide protection against climatic conditions of the outside environment and aggression of persons trying to break ...

Page 6: ...ltage use contacts C and NO For locks that open when voltage disappears while under voltage they are locked use contacts C and NC Lead voltage through these contacts from the power supply to the door lock If there is a contact on the door which is switched when the door is closed lead the contacts to the clips of input 1 Contact for monitoring the status of the door input 1 is taken into considera...

Page 7: ...e end of the data bus last module on the line must contain terminal resistor jumper inserted on the contacts of the J5 connection When using certain converters dividers and repeaters on the RS485 data bus it might be necessary to insert jumpers on the connections J4 and J6 which define resting state on the bus When using a converter supplied by the manufacturer GNOME485 it is not necessary to inst...

Page 8: ... proper connection of the module Area for setting the HW address Area with control elements for setting the general properties of the module Indicators are located in the individual parts of the status bar from the left Indicator of the state of communication with the module red color indicates error in communication flawless communication is indicated by green color Indicator of the process of sa...

Page 9: ... to the normal operational regime by itself Erasing cards from the memory Step 1 Step 2 Step 3 After having read the programming card for erasing the reader is set to programming regime Read cards that are to be rid of the access rights in the entry place in question After c 15 s after the last card the reader will go to the normal operational regime by itself Erasing all programmed cards Step 1 S...

Page 10: ...2N TELEKOMUNIKACE a s Mod anská 621 143 01 Praha 4 Czech Republic tel 420 261 301 111 fax 420 261 301 999 e mail sales 2n cz www 2n cz 2008 2N TELEKOMUNIKACE a s Praha OV 1350 v 2 1 ...

Reviews: