Overview of module’s features in various regimes of operation
Function
Regime of operation
autonomous offline online
Definition of access rights using programming cards
Signalization of reading a card and releasing the door lock
Acoustic signalization of alarm situations
Changing the parameters of regimes of operation and alarm
regimes
Definition of access rights from the PC
Visualization of the regime of the reading module, recording
events in an archive in the PC, viewing and working with events
Controlling the output of the reading module directly from the PC
Technical parameters
Dimensions of the mother board
81 x 81 x 25 mm
Power supply
10
÷
15 VDC
Max. power input
160 mA
ID technology
EM Marin, 125kHz
Max. number of access cards in the memory
748
Inputs
2x logical, non-potential
Output for door lock
1x relay switch contact 2 A / 24 V
Alarm output
Transistor output 5 V / 5 mA
Protective contact (tamper)
Opto-electric
Typical reading distance
2 cm (in panel)
Communication channel
RS485 galvanic non-separated
Alternative data output
WIEGAND (configurable)
Signalization
Piezzo- 3x LED (on the board)
Working temperature
-10
÷
+40°C
Max. relative humidity
75%, without condensation
Configurable operational parameters
Parameter
Possible values
Default value
Lock release duration
0
÷
255 s
7 s
Acoustic signalization of lock releasing
Yes / no
Yes
Maximum duration of door opening
0
÷
255 s
30 s
Duration of acoustic signalization of violation
0
÷
255 s
30 s
Duration of acoustic signalization of door broken open
0
÷
255 s
30 s
Duration of acoustic signalization of door open too long 0
÷
255 s
0 s
Function of the 2
nd
input
Leaving button /
handle contact
Leaving button