Recommendations for installation 

Reading module ATEUS 

®

 - APS mini uses passive RF/ID technology, sensitive to external 

RF  disturbance.  This  disturbance  may  come  via  radiation  from  the  surroundings  or  via 

supply cables. 
Therefore  it  is  necessary  to  avoid  installing  modules  close  to  possible  sources  of 

electromagnetic  field,  including  for  example  computer  monitors  (distance  at  least  3  cm) 

and various home and industrial appliances. It is also better to use recommended power 

supply (linear) to reduce disturbance coming via the cables. 
From this perspective it is also necessary to take into consideration mutual disturbing of 

the  reading  modules  –  for  proper  functioning  of  modules  it  is  necessary  to  keep  the 

distance of at least 50 cm. This distance can be negatively influenced by various metallic 

constructions (in case of doubts it is recommended to carry out practical test on the spot 

before the final installation). 
Proper  functioning  and  the  reading  distance  can  also  be  influenced  by  metal  surfaces 

close  to  the  antenna.  Such  objects  absorb  electromagnetic  field  and  may  disturb  the 

antenna of the module – also in this case we recommend practical test. 
It is recommended to install the chip card reader indoor on a wall, together with the door 

communicator  and  reader’s  antenna.  Installing  the  reader  indoors  will  provide  protection 

against climatic conditions of the outside environment and aggression of persons trying to 

break into the building. If only the antenna of the reader is located outside of the building it 

will not be possible to switch the door lock without authorization. Unauthorized switch of 

the lock can only be achieved by manipulating with the reader’s mother board. The mother 

board can be installed on the wall using installation box, which is supplied together with 

the board. 
 

Installation of the antenna module into the door communicator 

Correct  installation  of  the 

antenna  module  into  the  door 

communicator  can  be  seen  on 

picture  on  the  right.  Fix  the 

module  to  plastic  basis  of  the 

door  communicator  using  the 

screw  enclosed.  Hide  the 

microphone  cable  under  the 

antenna  module.  After  having 

fixed the module, connect it with 

the reader’s mother board using 

the enclosed cable. Connect the 

cable  to  the  X3  connector  on 

the mother board. 
 

Summary of Contents for 91341611WE

Page 1: ...2N APS MINI ENTRYCOM SET Order No 91341611WE User and service manual Version 2 1 ...

Page 2: ...WE EntryCom Set 9134162WE Standalone reader module 9134167WE Reader module with attendance keypad 91341612WE Built in reader module for EntryCom 91341631E Converter RS485 Ethernet 9134164E PC mini reader 9134165E Chip card 9134166E Chip key fob ...

Page 3: ...ut by the reading module autonomously without the need to be connected to the PC After connecting to the PC the system offers more functions thanks to online status monitoring and to archiving of events from the connected reading modules The reading module integrating all circuits necessary for one reading place and one door is the basic hardware element of the APS mini access system Regimes of op...

Page 4: ...ccess cards in the memory 748 Inputs 2x logical non potential Output for door lock 1x relay switch contact 2 A 24 V Alarm output Transistor output 5 V 5 mA Protective contact tamper Opto electric Typical reading distance 2 cm in panel Communication channel RS485 galvanic non separated Alternative data output WIEGAND configurable Signalization Piezzo buzzer 3x LED on the board Working temperature 1...

Page 5: ...objects absorb electromagnetic field and may disturb the antenna of the module also in this case we recommend practical test It is recommended to install the chip card reader indoor on a wall together with the door communicator and reader s antenna Installing the reader indoors will provide protection against climatic conditions of the outside environment and aggression of persons trying to break ...

Page 6: ...ltage use contacts C and NO For locks that open when voltage disappears while under voltage they are locked use contacts C and NC Lead voltage through these contacts from the power supply to the door lock If there is a contact on the door which is switched when the door is closed lead the contacts to the clips of input 1 Contact for monitoring the status of the door input 1 is taken into considera...

Page 7: ...e end of the data bus last module on the line must contain terminal resistor jumper inserted on the contacts of the J5 connection When using certain converters dividers and repeaters on the RS485 data bus it might be necessary to insert jumpers on the connections J4 and J6 which define resting state on the bus When using a converter supplied by the manufacturer GNOME485 it is not necessary to inst...

Page 8: ... proper connection of the module Area for setting the HW address Area with control elements for setting the general properties of the module Indicators are located in the individual parts of the status bar from the left Indicator of the state of communication with the module red color indicates error in communication flawless communication is indicated by green color Indicator of the process of sa...

Page 9: ... to the normal operational regime by itself Erasing cards from the memory Step 1 Step 2 Step 3 After having read the programming card for erasing the reader is set to programming regime Read cards that are to be rid of the access rights in the entry place in question After c 15 s after the last card the reader will go to the normal operational regime by itself Erasing all programmed cards Step 1 S...

Page 10: ...2N TELEKOMUNIKACE a s Mod anská 621 143 01 Praha 4 Czech Republic tel 420 261 301 111 fax 420 261 301 999 e mail sales 2n cz www 2n cz 2008 2N TELEKOMUNIKACE a s Praha OV 1350 v 2 1 ...

Reviews: