background image

4

BE PREPARED 

Practice the following steps to prepare you and your family in the event of a fi re:

•  Perform fi re drills regularly. Use them to assure recognition of an alarm 

signal. 

•  Draw a fl oor plan and show two exits from each room. It is important 

that children be instructed carefully, because they tend to hide in times 
of crisis.

•  Establish one meeting place outside the home. Insist that everyone 

meet there during an alarm. This will eliminate the tragedy of someone 
reentering the house for a missing member who is actually safe.

•  If you have children and/or physically challenged people residing in your 

household, use window decals to help emergency personnel identify the 
sleeping quarters of these individuals.

WARNING

Smoke alarms CANNOT provide warnings for fi res resulting from 
explosions, smoking in bed or other furniture, ignition of fl ammable 
liquids, vapors and gases, children playing with matches or lighters.

LIMITED WARRANTY

This 2GIG Technologies product is warranted against defects in material 
and workmanship for two (2) years. 

This warranty extends only to 

wholesale customers

 who buy direct from 2GIG Technologies or through 

2GIG Technologies’ normal distribution channels. 

2GIG Technologies does 

not warrant this product to consumers.

 Consumers should inquire from 

their selling dealer as to the nature of the dealer’s warranty, if any. 

There 

are no obligations or liabilities on the part of 2GIG Technologies for 
consequential damages arising out of or in connection with use or 
performance of this product or other indirect damages with respect 
to loss of property, revenue, or profi t, or cost of removal, installation, 
or reinstallation.

 All implied warranties, including implied warranties for 

merchantability and implied warranties for fi tness, are valid only until the 
warranty expires. 

This 2GIG Technologies Warranty is in lieu of all other 

warranties express or implied.

SERVICING INFORMATION:

All products returned for warranty service require a Return Product 
Authorization Number (RPA#). Contact 2GIG Technologies at 1-866-670-1591 
for an RPA# and other important details.
For additional warranty and compliance information, visit our Web site at: 
www.2gig.com

IMPORTANT!!!

Radio controls provide a reliable communications link and fi ll an important 
need in portable wireless signaling. However, there are some limitations which 
must be observed.

•  For U.S. installations only: The radios are required to comply with FCC 

Rules and Regulations as Part 15 devices. As such, they have limited 
transmitter power and therefore limited range.

•  For Canadian installations only: The radios are required to comply with 

Industry Canada (IC) Rules and Regulations. As such, they have limited 
transmitter power and therefore limited range.

•  A receiver cannot respond to more than one transmitted signal at a time 

and may be blocked by radio signals that occur on or near their operating 
frequencies, regardless of code settings. 

•  Changes or modifi cations to the device may void FCC or IC compliance.
•  Infrequently used radio links should be tested regularly to protect against 

undetected interference or fault.

•  A general knowledge of radio and its vagaries should be gained prior 

to acting as a wholesale distributor or dealer, and these facts should be 
communicated to the ultimate users.

REGULATORY COMPLIANCE

This device complies with IC Rules and Part 15 of the FCC Rules. Operation is 
subject to the following two conditions: (1) This device may not cause harmful 
interference. (2) This device must accept any interference received, including 
interference that may cause undesired operation.

WARNING! LIMITATIONS OF SMOKE ALARMS

Wireless smoke alarms are very reliable, but may not work under all conditions. 
No fi re alarm provides total protection of life or property. Smoke alarms are not 
a substitute for life insurance.

Smoke alarms require a source of power to work. 

This smoke alarm will 

not operate and the alarm will not sound if batteries are dead or not installed 
properly. 

Smoke alarms may not be heard.

  A sound sleeper or someone who has 

taken drugs or alcohol may not awaken if the alarm is installed outside a 
bedroom. Closed or partially closed doors and distance can block sound. This 
alarm is not designed for the hearing impaired.

Smoke alarms may not always activate and provide warning early 
enough.

 Smoke alarms only activate when enough smoke reaches the alarm. 

If a fi re starts in a chimney, wall, roof, on the other side of closed doors, or on 
a different level of the property, enough smoke may not reach the alarm for it 
to alarm.
Smoke alarms are a signifi cant help in reducing loss, injury and even death. 
However, no matter how good a detection device is, nothing works perfectly 
under every circumstance and we must warn you that you cannot expect a 
smoke alarm to ensure that you will never suffer any damage or injury. 
Current studies have shown smoke alarms may not awaken all sleeping 
individuals. It is the responsibility of individuals in the household that are 
capable of assisting others to provide assistance to those who may not be 
awakened by the alarm sound, or to those who may be incapable of safely 
evacuating the area unassisted.

FIRE PREVENTION AND ESCAPE

The purpose of an early warning smoke alarm is to detect the presence of fi re 
in its early stages and sound an alarm giving the occupants time to exit the 
premises safely.

AVOID FIRE HAZARDS

No detection device can protect life in all situations. Therefore, safeguards 
should be taken to avoid potentially dangerous situations as follows:

• Do 

not

 smoke in bed.

• Do 

not

 leave children home alone.

• Never

 clean with fl ammable liquids such as gasoline.

•  Properly store materials. Use general good housekeeping techniques 

to keep your home neat and tidy.  A cluttered basement, attic, or other 
storage area is an open invitation to fi re.

•  Use combustible materials and electrical appliances carefully and only 

for their intended uses. 

Do not

 overload electrical outlets.

• Do 

not

 store explosive and/or fast burning materials in your home.

•  Even after proper precautions have been taken, fi res can start. 

Be 

prepared.

IN CASE OF FIRE 

In the event of a fi re:

•  Leave immediately. Don’t stop to pack or search for valuables. 
•  In heavy smoke, hold your breath and stay low, crawl if necessary. The 

clearest air is usually near the fl oor.  

•  If you have to go through a closed door, carefully feel the door and door 

knob to see if undue heat is present. If they seem cool, brace your foot 
against the bottom of the door with your hip against the door and one 
hand against the top edge. Open it slightly. If a rush of hot air is felt, slam 
the door quickly and latch it. Unvented fi re tends to build up considerable 
pressure. Be sure all members of the household realize and understand 
this danger.

•  Use your neighbor’s phone or a street fi re alarm box to call the fi re 

department. The job of extinguishing the fi re should be left to the 
professionals.

Summary of Contents for 2GIG-SMKT2-345

Page 1: ... 6 Attach the unit to the base as follows Line up the raised alignment tab on the lip of the unit with the alignment arrow on the base See Figure 3 Insert the unit into the base and turn clockwise approximately 15 degrees It should snap firmly into place IMPORTANT The unit cannot be attached to the base if no batteries are installed PROGRAM SMOKE ALARM INTO THE CONTROL PANEL Before testing the smo...

Page 2: ...mber 230802 as follows 1 To remove the unit from the mounting base grasp the unit and turn it counterclockwise approximately 15 degrees 2 Remove the batteries 3 Slide a flat blade screwdriver in the slot on the alarm cap and gently push the handle down to pry the alarm cap up and off See Figure 4 4 Squeeze the optical chamber where indicated and pull it up and away from the optical base and discar...

Page 3: ... The additional areas include the basement bedrooms dining room furnace room utility room and hallways not protected by the required smoke alarms The installation of smoke alarms in kitchens attics finished or unfinished or garages is not normally recommended as these locations occasionally experience conditions that can result in improper operation Since regulations pertaining to smoke alarm dete...

Page 4: ...rt 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation WARNING LIMITATIONS OF SMOKE ALARMS Wireless smoke alarms are very reliable but may not work under all conditions No fire alarm provides total protection of life or ...

Page 5: ...ancrage fournis 6 Fixer l appareil à la base de la façon suivante Aligner l ergot d alignement situé sur la couronne de l appareil sur la flèche d alignement de la base Voir la figure 3 Insérer l appareil sur la base et tourner sur environ 15 degrés dans le sens des aiguilles d une montre Il devrait s enclencher en place fermement Important L appareilnepeutêtrefixéàlabasesilespilesnesontpasinstall...

Page 6: ... et le tourner sur environ 15 degrés dans le sens contraire des aiguilles d une montre 2 Enlever les piles 3 Insérer un tournevis à lame plate dans la fente du couvercle du détecteur et pousser doucement la poignée du tournevis vers le bas pour faire levier et soulever le couvercle pour le retirer Voir la figure 4 4 Pincer la chambre optique à l endroit indiqué la soulever et la sortir du support ...

Page 7: ...avec les autorités compétentes Lorsque la sécurité publique est primordiale ces autorités peuvent être un ministère fédéral provincial une autorité régionale municipale ou encore un responsable tel que le chef des pompiers le chef du service des incendies le chef du bureau de prévention des incendies ministère de la main d oeuvre ou de la santé un inspeceur en électricité ou toute autre personne p...

Page 8: ... dispositif ne doit pas causer d interférences nuisibles et 2 ce dispositif doit accepter toute interférence reçue y compris les interférences pouvant entraîner des conditions de fonctionnement indésirables AVERTISSEMENT LIMITES DE FONCTIONNEMENT DES DÉTECTEURS DE FUMÉE Les détecteurs de fumée sans fil sont très fiables mais ils ne fonctionnent pas dans certaines conditions Aucune alerte d incendi...

Reviews: