30
2GIG EDGE User Guide
Transmit a Duress Signal when System is
Disarmed
To transmit a user duress report when the system is
disarmed:
1 .
At the Home screen or from one of the menus,
press and hold the 2GIG logo .
2 .
At the
Keypad
, enter the Duress Code .
The system will return to the Home screen, and the
duress signal is sent to the Central Station .
NOTE:
for Duress Code activation instructions .
System Logo
Enter the Duress Code
In the Event of a Burglary Alarm
If one or more armed sensors are tripped while the
system is armed in Stay or Away Mode, an alarm
condition will occur, and the system’s alarm siren will
sound .
If an
Entry Delay
sensor is tripped while the system
is armed in Stay or Away Mode, the
Entry Delay
countdown starts to give you time to disarm the system .
If the system is not disarmed before the countdown
expires, an alarm condition occurs, and the system’s
alarm siren will sound .
If more than one armed sensor is tripped, the system
displays the triggered sensors in chronological order .
Alarms Screen—Multiple Alarms in Chronological Order
Silencing the Alarm Sounder (for False Alarms)
If the system is in an active alarm state, any person with an active user code can silence the sounder by disarming the
system .
»
If you disarm the system BEFORE the Abort Window Dialer Delay countdown expires
, the system
cancels the alarm and stops the alarm report from being transmitted to the Central Station .
»
If you disarm the system AFTER the Abort Window Dialer Delay countdown expires
, the system
silences the alarm and transmits an alarm cancellation report to the Central Station .
NOTE:
Consult your installer to determine how the
Alarm Abort Window Dialer Delay
feature is configured on
your system (15-45 seconds). This setting specifies the number of seconds end users have to manually abort
the alarm, in the event of a false alarm . For
ANSI/SIA CP-01-2010
compliance, the default setting is 30 seconds .
For
UL 1023: Household Burglar Alarm Units
compliance, this setting may be configured to a maximum of 45
seconds .