6
Through parameter setting, it can be set to
For Modbus protocol, see 9.5rs485 communication function (MODBUS-RTU) for details
Fel!
Hittar inte referenskälla.Fel! Hittar inte referenskälla.
For BACnet protocol, see 9.6rs485 communication function (BACnet ms/tp) for details
Fel!
Hittar inte referenskälla.Fel! Hittar inte referenskälla.
4.2.1.4 Bluetooth communication
Support Bluetooth 4.0 communication of Android 6.0 and above systems,and use
MODBUS-RTU protocol.
4.2.1.5 Temperature interface
Pt-1000 input.
Default two-wire system, optional four wire system.
Measuring range: When the medium is water, the range is (0 ~ 130)
℃
When the medium is other, the range is (-30 ~ 175)
℃
Temperature difference range: (3 ~ 70) K.
4.2.2 Display
(1) 128 x 64 full dot matrix LCD display
(2) Language English
(3) Display units: "instantaneous flow", "cumulative flow", "power", "cumulative heat"
4.2.3 Power supply
DC 18 ~ 36V
AC 100 ~ 240V, 48 ~ 62Hz
4.2.4 Ambient temperature
-10
℃
~ +60
℃
(when AC power supply)
-10
℃
~ +50
℃
(DC power supply)
4.2.5 Protection grade
IP65
4.2.6 Cable access hole
m20x15 internal thread
4.2.7 Terminal plug-in connector
(wiring diameter 0.3 ~ 1.5mm2)
4.2.8 The shell
is made of cast aluminum alloy, and the surface is coated with pure
polyester plastic powder.
4.3 Sensor
Threaded sensor
4.3.1.1 Normal diameter
DN10
~
40
4.3.1.2 Appearance dimension