2. Programme
FOR ONE COFFEE CUP -
Press
for 3 seconds key
“MENU” to get access to programme menu.
Press
the key
“+” or “-” to slide the menu options, select “time dose 1”
pressing
key “OK”; using key “+” or “-” it’s possible to
increase or decrease the erogation time, which is displayed
in seconds (3 numbers) and cents of seconds (2 numbers)
to set and refine the released dose. After setting parameter
of time
press
again key “OK” to confirm and exit. To exit from
programme menu
press
“ESC”.
FOR TWO COFFEE CUPS – the same as for one cup, just
positioning on parameter written “time dose 2”.
The maximum time you can set is 640 seconds for all options.
STAND-BY TIME – It is the time after which the display en-
ters in power saving mode.
Press
for 3 seconds key
“MENU” to get access to programme menu.
Press
the key
“+” or “-” to slide the menu options, select “ STAND BY
time”. Select it
pressing
key “OK”, then using “+” or “-” it’s
possible to increase or decrease the time, which is displayed
in seconds. After setting parameter of time
press
again key
“OK” to confirm and exit. To exit from programme menu
press
“ESC”.
S
ET WRITTEN “READY” – Keep touched for 3
seconds key “MENU” to get access to programme menu.
Press
the key “+” or “-” to slide the menu options, select
“BAR message”. ”. Select it
pressing
key
“OK”, then using key “MAN” move the cursor till the point
you want the written begins. Use key “+” and “-” to slide the
alphanumeric list; to stop at choosen character and move to
next, use key “MAN”. Repeat the procedure till the
choosen code for stand by mode is complete. To confirm
and exit
press "O
K”. To exit from programme menu
press
“ESC”.
BRIGHTNESS – To set the display brightness. T
Press
for 3
seconds key “MENU” to get access to programme menu.
press
the key “+” or “-” to slide the menu options, select
“brightness”
pressing
key “OK”, then using “+” or “-” it’s pos-
sible to increase or decrease the brightness from 0 to
100%. To confirm and exit
press
“OK”. To exit from
programme
menu
press
“ESC”.
TOTAL COUNT OF EROGATED DOSES – Provides infor-
mation on the total doses erogated by the grinder. To dis-
play it,
press
for 3 seconds key “MENU” to get access to
programme menu.
Press
the key “+” or “-” to slide the menu
options, select “total count”
pressing
key “OK”.
PARTIAL COUNT OF EROGATED DOSES – Provides in-
formation on the quantity of erogated doses from the last
reset (usually to count the erogated doses during the day/
week). To reset
press
for 3 seconds key “MENU” to get ac-
cess to programme menu.
press
the key “+” or “-” to slide
the menu options, select “partial count”.
Keep touched key “MAN” untill the value returns to zero. To
exit from programme menu
press
“ESC”.
CHANGE LANGUAGE – Keep touched for 3 seconds key
“MENU” to get access to programme menu,
press key
“+”
or “-” to slide the menu options, select “CHANGE LAN-
GUAGE”: select
pressing
key “OK”, then using “+” or “-” it’s
possible set the choosen language among the available
ones. After choosing the language,
press the
key “OK” to
confirm and exit. To exit from programme
menu press the
key "ESC".
GB
Q50 “
ELECTRONIC
” VERSION
Warning: to stop the provision of coffee
press
any of
the 4 keys of display.
Operation
1. before inserting the plug in the socket or turning on the main
switch upstream from the machine, ensure that the switch on
the machine in on position “0”. Insert the shutter that closes the
top container and check that it slides in its seat.
Fit the container in its seat,
pressing
at the side with your
fingers until it is firmly in place, then fix it to the ring nut of
milling regulation with the appropriate screw supplied with
the apparatus, match the hole on the beans container with
the one on the ring nut.
The coffee grinder is now ready for work. Pour the coffee
beans into the top container. Open the shutter and insert
the plug in the socket, then turn the machine switch to posi-
tion “I”. Now the display will be ignited visualizing the written
“READY”; the grinder is ready to erogate the required doses
(from one to two) or to be programmed. Put the door filter in
the appropriate staple and then is possible to proceed with
the distribution of the milled coffee in this way:
- single dose:
press
the button with a cup
- double dose: press the button with two cups
- manual dose: pressing key “MAN”, the grinder starts to
work. To stop erogation press again key “MAN” (the
grinder automatically stops after 4 minutes).
29