Chapter 23 VLAN Stacking
VES1724-56 User’s Guide
212
23.4.1 Port-based Q-in-Q
Port-based Q-in-Q lets the Switch treat all frames received on the same port as the same VLAN
flows and add the same outer VLAN tag to them, even they have different customer VLAN IDs.
Role
Select Normal to have the Switch ignore frames received (or transmitted) on this port with VLAN
stacking tags. Anything you configure in SPVID and Priority of the Port-based QinQ or the
Selective QinQ screen are ignored.
Select Access Port for ingress ports at the edge of the service provider's network.
Select Tunnel Port (available for Gigabit ports only) for egress ports at the edge of the service
provider's network. Select Tunnel Port to have the Switch add the Tunnel TPID tag to all
outgoing frames sent on this port.
In order to support VLAN stacking on a port, the port must be able to allow frames of 1526 Bytes
(1522 Bytes + 4 Bytes for the second tag) to pass through it.
Tunnel
TPID
TPID is a standard Ethernet type code identifying the frame and indicates whether the frame
carries IEEE 802.1Q tag information. Enter a four-digit hexadecimal number from 0000 to FFFF
that the Switch adds in the outer VLAN tag of the frames sent on the tunnel port(s). The Switch
also uses this to check if the received frames are double-tagged.
The value of this field is 0x8100 as defined in IEEE 802.1Q. If the Switch needs to communicate
with other vendors’ devices, they should use the same TPID.
Note: You can define up to four different tunnel TPIDs (including
8100
) in this screen at a time.
Apply
Click Apply to save your changes to the Switch’s run-time memory. The Switch loses these
changes if it is turned off or loses power, so use the Save link on the top navigation panel to save
your changes to the non-volatile memory when you are done configuring.
Cancel
Click Cancel to begin configuring this screen afresh.
Table 91
Advanced Application > VLAN Stacking (continued)
LABEL
DESCRIPTION
Содержание VES1724-56
Страница 17: ...17 PART I User s Guide...
Страница 18: ...18...
Страница 22: ...Chapter 1 Getting to Know Your Switch VES1724 56 User s Guide 22...
Страница 51: ...51 PART II Technical Reference...
Страница 52: ...52...
Страница 57: ...Chapter 7 System Status and Port Statistics VES1724 56 User s Guide 57...
Страница 96: ...Chapter 8 Basic Setting VES1724 56 User s Guide 96...
Страница 128: ...Chapter 9 VDSL Setup VES1724 56 User s Guide 128...
Страница 148: ...Chapter 10 VLAN VES1724 56 User s Guide 148 Figure 84 Port Based VLAN Setup Port Isolation...
Страница 326: ...Chapter 35 DHCP VES1724 56 User s Guide 326...
Страница 400: ...Appendix A Common Services VES1724 56 User s Guide 400...